摘要
The heat flux deposition pattern on the toroidal limiters installed in HT-7 was simulated with ANSYS code. The simulation model was established with the ripple of the magnetic field. The heat deposition pattern and temperature distribution on the surface of the toroidal linfiters were obtained. A comparison of the results obtained with and without the shaped tiles, used to reduce the heat flux on the leading edge of the limiters, was made. The maximum heat load allowed at the leading edge was about 1.8 MW/m2 because of the poor power removing capacity on the ends of the limiters. This approach can also be applied to other devices with a limiter configuration in a circular cross-section shape.
The heat flux deposition pattern on the toroidal limiters installed in HT-7 was simulated with ANSYS code. The simulation model was established with the ripple of the magnetic field. The heat deposition pattern and temperature distribution on the surface of the toroidal linfiters were obtained. A comparison of the results obtained with and without the shaped tiles, used to reduce the heat flux on the leading edge of the limiters, was made. The maximum heat load allowed at the leading edge was about 1.8 MW/m2 because of the poor power removing capacity on the ends of the limiters. This approach can also be applied to other devices with a limiter configuration in a circular cross-section shape.
基金
National Natural Science Foundation of China(No.10475080)
the Foundation of Hefei Institutes of Physical Science(No.2006YZJJ-1)