期刊文献+

磁共振强磁场中保持稳定悬浮及超顺磁性的微粒粒度研究

Study on the Size of Particals Keep Stable and Uperparamagnetism in MRI High Magnetic Fields
下载PDF
导出
摘要 用超顺磁性氧化铁制备磁共振造影剂的多篇报道中,Fe3O4磁粒的尺寸大致在15~50nm之间。根据超顺磁性理论推导出显示超顺磁现象的临界尺寸理论值为25nm,在1.5T磁共振磁场中的临界值为7.1nm。分析了在强磁场中包覆有表面活性剂的Fe3O4磁粒的粒径在大于理论计算的临界尺寸时,仍有可能保持超顺磁状态。根据磁学理论,分析了磁共振造影剂稳定的机理;推导出在磁共振磁场中,Fe3O4磁粒在造影剂中稳定悬浮的极限尺寸为13.3nm。指出造影剂中的Fe3O4磁粒既能稳定悬浮又具有超顺磁性的合适尺寸为10nm左右。 Superparamagnetic iron oxide contrast agents have been reported by many researches. The diameter of Fe3O4 in these agents is 15 -50 nm. The critical size which developed based on superparamagnetic theory is 25 nm. And the critical size is 7. 1 nm in 1.5 T MRI high magnetic fields, the diameter of Fe3O4 coating suspending agents on the surface would remain superparamagnetic state is analyzed when their particle size is larger than the size theoretically in MRI high magnetic fields. Based on magnetic theory, the mechanism of stability of contrast agent was analyzed, and the critical size which Fe3O4 magnetic microparticles keep stable in the contrast agent is 13.3 nm developed. The proper occluder size which Fe3O4 magnetic microparticles keep stable and Uperparamagnetism in the contrast agent is 10nm reported.
作者 桂维玲
出处 《科学技术与工程》 2008年第8期2166-2168,共3页 Science Technology and Engineering
基金 山东省科技厅计划项目(003130103) 山东省教育厅科技计划项目(JOOK51)资助
关键词 超顺磁性氧化铁 磁共振造影剂 临界尺寸 稳定悬浮 superparamagnetic iron oxide contrast agent for abdomen MRI critical size suspension stability
  • 相关文献

参考文献9

二级参考文献40

  • 1刘明礼,梁荣玲.磁共振成像中的造影剂[J].中国医学物理学杂志,1992,9(1):24-26. 被引量:2
  • 2王毅翔,沈天真,陈星荣,吴怀瑛,陈根芳,陶可.超顺磁性氧化铁胶体用作网状内皮系统磁共振对比剂的实验研究[J].中国医学影像学杂志,1994,2(3):181-185. 被引量:5
  • 3黄双,杨眉,徐松,王焕磊.微乳液法制备纳米Fe_3O_4磁性颗粒的研究[J].武汉工程职业技术学院学报,2006,18(3):39-44. 被引量:12
  • 4[1]Som PM. Detection of metastasis in cervical lymph nodes: CT and MRI criteria and differential diagnosis [J]. AJR Am J Roentgenol,1992, 158(5): 961-5.
  • 5[2]Wagner S. Benign lymph node hyperplasia and lymph node metastases in rabbits: animal models for magnetic resonance lymphography [J]. Invest Radiol, 1994, 29(2): 364-9.
  • 6[5]Weissleder R, Elizondo G, Wittenerg J, et al. Ultrasmall superparamagnetic iron oxide: an intravenous contrast agent for assessing lymph nodes with MR imaging [J]. Radiology, 1990, 175(3): 494-8.
  • 7[6]Mack MG, Blazer JO, Straub R, et al. Superparamagnetic iron oxideenhanced MR imaging of head and neck lymph nodes [J].Radiology, 2002, 222(2): 239-45.
  • 8[7]Berllin MF, Roy C, Kinkel K, et al. Lymph node metastases: safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles-initial clinical experience[J]. Radiology, 1998,207(5): 799-808.
  • 9都有为,磁性材料及器件,1990年,3卷,20页
  • 10薛荣华,南京大学学报,1986年,4卷,11页

共引文献103

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题