期刊文献+

PASCAL动态轮廓眼压计及临床运用体会 被引量:5

PASCAL dynamic contour ton-ometer and clinical application
下载PDF
导出
摘要 眼压测量在青光眼的诊治中占有非常重要的地位,中央角膜厚度对Goldmann压平眼压计的眼压测量值有重大影响,使Goldmann眼压计的"金标准"地位发生动摇;新近研发的动态轮廓眼压计采用轮廓匹配和压力传感器原理来测量眼压,理论上可克服Goldmann眼压计在眼压测量上的缺陷。本文简要介绍这种新型眼压计的测量原理、结构组成、测量过程、使用方法、与Goldmann眼压计的比较及临床运用的体会。 sure plays an The measurement of intraocular presimportant role in diagnosis and treatment of glaucoma. The fact that center cornea thickness affects the results of the Goldmann applanation tonometer (GAT) made the "gold standard" position of GAT changed. The latest developed dynamic contour tonometer using contour matching principle and pressure sensor principle to measure intraocular pressure can overcome the shortcomings of GAT in theory. This article mainly introduces the principal of measurement, composition, process of measurement, and the using methods of this new tonometer. Further more,there is a comparison with GAT in clinical application.
出处 《眼科新进展》 CAS 2008年第5期391-393,398,共4页 Recent Advances in Ophthalmology
关键词 青光眼 眼压测量 动态轮廓眼压计 Goldmann压 平眼压计 glaucoma IOP measurement dynamic contour tonometer Goldmann applanation tonometer
  • 相关文献

参考文献15

  • 1周和政,沈政伟,金中秋,王柏川,鄢俊杰.辩证地认识眼压在青光眼诊断中的地位[J].美中国际眼科杂志,2002,2(2):20-23. 被引量:13
  • 2肖明,孙兴怀.高眼压症与角膜厚度[J].中国实用眼科杂志,2001,19(4):276-278. 被引量:13
  • 3詹素华,庞国祥,金玉梅,孙玉敏.角膜中央厚度与眼压读数[J].眼科新进展,2001,21(2):126-127. 被引量:12
  • 4Kanngiesser HE,Robert YC.Dynamic contour tonometry-DCT:A new method for the direct and continuous measurement of intraocular pressure (IOP)[J].ARVO Poster 2002 No,B276.
  • 5Kaufman C,Bachmann LM,Thiel MA.Intraocular pressure measurement using dynamic contour tonometry after laser in situ keratomileusis[J].Invest Ophthalmol Vis Sci 2003;44:3790-3794.
  • 6Punjabi OS,Kniestedt C,Stamper RL,Lin SC.Dynamic contour tonometry:principle and use[J].Clin Exp Ophthalmol 2006;34:837-840.
  • 7Kanngiesser HE,Kniestedt C,Robert YC.Dynamic contour tonometry:presenting a new tonometer[J].J Glaucoma 2005;14:344-350.
  • 8Kniestedt C,Lin S,Choe J,Bostrom A,Nee M,Stamper RL.Clinical comparison of contour and applanation tonometry and their relationship to pachymetry[J].Arch Ophthalmol 2005;123:1532-1537.
  • 9孟海林,冯梅艳,杜献芳,张东魁.LASIK术后眼压测量值的变化分析[J].眼科新进展,2007,27(8):616-618. 被引量:8
  • 10Pepose JS,Feigenbaum SK,Qazi MA,Sanderson JP,Roberts CJ.Changes in corneal biomechanics and intraocular pressure following LASIK using static,dynamic,and noncontact tonometry[J].Am J Ophthalmol 2007;143:39-47.

二级参考文献18

  • 1施爱群,孙心铨,王松柏.正常人角膜各部位厚度超声测量结果[J].中日友好医院学报,1994,8(3):155-155. 被引量:3
  • 2高宗峰.安徽省桐城县青光眼流行病学调查[J].中华眼科杂志,1995,31(2):149-151. 被引量:26
  • 3朱格非,黄菊天.正常人眼的角膜厚度[J].眼科研究,1995,13(3):211-213. 被引量:7
  • 4胡铮,彭佑恩.北京市顺义县青光眼流行病学调查[J].中华眼科杂志,1989,25(2):115-119. 被引量:86
  • 5张淑芳,中华眼科杂志,1981年,17卷,226页
  • 6Chatterjee A,Shah S,Bessant DA,Naroo SA,Doyle SJ.Reduction in intraocular pressure after excimer laser photorefractive keratectomy correlation with pretreatment myopia[J].Ophthalmology 1997;104(3):355-359.
  • 7Goldmarm H.Un nouveru tonometre a applanfion[J].Bullmenn Soc Fr Ophthalmol 1954;67(4):47.
  • 8Wolfs RCW.Distribution of central corneal thickness and its association with intraocular pressure:the Rotterdam Study[J].Am J Ophthalmol 1997;123(4):767-772.
  • 9Foumier AV,Pobetenev M,Lemive J.Intraocular pressure change measured by Goldmann tonometer after laser in situ keralomiteusis[J].J Cataract Refract Surg 1998;24(7):905.
  • 10Tuunanmem TH,Hamalainen P,Mali M.Effect of photorefracfive keratectomy on the accuracy of pneumatonometer reading in rabbits[J].Invest Ophthalmol Vis Sic 1996;37(9):1810.

共引文献39

同被引文献58

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部