期刊文献+

基于双目立体视觉的光笔式三坐标测量系统 被引量:12

Study on 3D-Coordinate Measurement Technology Using Light-pen Based on Binocular Stereoscopic Vision System
下载PDF
导出
摘要 提出了一种基于双目立体视觉系统的光笔式三坐标测量系统。该系统基于接触式测量方式,以带点光源的光笔作为接触测量工具。首先,对摄像机进行了高精度的标定,建立了双目立体视觉系统模型;其次,通过左右摄像机拍摄的二维图像,将两幅图像中的点进行匹配,获得光笔上的LED光斑中心三维坐标;然后,由一系列LED光斑中心的三维坐标拟合直线,从直线上得到笔尖的三维坐标。实验结果表明,该方法实现了对物体的接触式测量,具有结构简单、成本低的优点,并且具有较高的精度。 A novel 3D--coordinate measurement system using light--pen based on binocular stereoscopic vision system was presented. Based on contact measurement mode the system used light--pen with light sources as a contact measurement tool. Firstly, the cameras were calibrated high accurately, and the stereoscopic vision system model was established. Secondly, the 3D coordinates of the center of LED on the light--pen were achieved through matching the 2D images grabbed by the two cameras. Then,a series of the 3D coordinates of the center of LED were used for fitting straight line,and the 3D coordinates of the pen--points can be obtained from the line. The test results show that this system realizes contact measurement on objects, with virtues such as simple configuration and low cost,and possesses high accuracy.
机构地区 中国海洋大学
出处 《中国机械工程》 EI CAS CSCD 北大核心 2008年第8期896-899,共4页 China Mechanical Engineering
基金 国家自然科学基金资助项目(60772057)
关键词 光笔 光笔式三坐标测量系统 双目立体视觉 重心法 light-- pen 3D-- coordinate measurement system using light -- pen binocular stereoscopic vision method of barycenter
  • 相关文献

参考文献5

二级参考文献23

  • 1WANG Qing-you.Application technology of CCD[M].Tianjing:Tianjing University Press,2000.30-40.(in Chinese).
  • 2YU Dao-yin,TAN Hen-ying.Engineering optics[M].Beijing:China Machine Press,1999.256-257.(in Chinese).
  • 3TAPLIN S,PODOLEANU A GH,WEBB D J,et al.Displacement sensor using channelled spectrum dispersed on a linear CCD array[J].Electronics Letters,1993,29 (10):896-897.
  • 4RAMESH SATHAPPAN,BARTLETT MATTHEW,JIANG Hua-bei.CCD-based spectroscopic imaging system for biodiagnostics[J].Critical Reviews in Biomedical Engineering,1998,26(5):413.
  • 5Roger Y. Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE. Journal of Robotics and Automation, 1987, RA-3(4):323-344.
  • 6Janne H. Geometric camera calibration using circular control points. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(10):1066-1077.
  • 7Zhengyou Zhang. A flexible new technique for camera calibration. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(11):1330-1334.
  • 8Alan M. Mclvor. Nonlinear calibration of a laser stripe profiler. Optical Engineering, 2002,41(1):205-212.
  • 9Juyang Weng. Camera calibration with distortion models and accuracy evaluation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1992, 14(10):965-980.
  • 10K. Vijayan Asari. A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation. IEEE Transactions on Medical Imaging, 1999,18(4):345-354.

共引文献165

同被引文献106

引证文献12

二级引证文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部