Dosimetric parameters of palladium-103 brachytherapy source with Monte Carlo simulation 被引量:3

Dosimetric parameters of palladium-103 brachytherapy source with Monte Carlo simulation
原文传递
导出
摘要 Before clinical application of a new source, the dosimetric parameters of the source should be accu- rately determined. This work is dedicated to the Monte Carlo method to calculate dosimetric parameters as recommended by the American Association of Physicists in Medicine (AAPM) TG-43 guidelines for model ADVANTAGETM palladium-103 source and, through comparison with data from another published report for the same source, presents a suggested dataset for clinical applications. From these calcula- tions, tables are presented for the radial dose function and the anisotropy function of palladium-103 brachytherapy source. The dose rate constants are found to be 0.671 (cGyh-1U-1) in liquid water and 0.673 (cGyh-1U-1) in Solid WaterTM. And the anisotropy constants in liquid water and Solid WaterTM are found to be 0.864 and 0.865 respectively. Comparison with the previous study shows that our results of dosimetric parameters are in good agreement with those measured and calculated by Meigooni et al. (2006) both in Water and Solid WaterTM. Before clinical application of a new source, the dosimetric parameters of the source should be accurately determined. This work is dedicated to the Monte Carlo method to calculate dosimetric parameters as recommended by the American Association of Physicists in Medicine (AAPM) TG-43 guidelines for model ADVANTAGETM palladium-103 source and, through comparison with data from another published report for the same source, presents a suggested dataset for clinical applications. From these calcula- tions, tables are presented for the radial dose function and the anisotropy function of palladium-103 brachytherapy source. The dose rate constants are found to be 0.671 (cGyh-1U-1) in liquid water and 0.673 (cGyh-1U-1) in Solid WaterTM. And the anisotropy constants in liquid water and Solid WaterTM are found to be 0.864 and 0.865 respectively. Comparison with the previous study shows that our results of dosimetric parameters are in good agreement with those measured and calculated by Meigooni et al. (2006) both in Water and Solid Water^TM.
出处 《Chinese Science Bulletin》 SCIE EI CAS 2008年第9期1304-1309,共6页
基金 Supported by the National Natural Science Foundation of China (Grant Nos. 10775174 and 90206044)
关键词 短程治疗 钯-103 测量参数 数学模型 brachytherapy, Monte Carlo, model ADVANTAGE^TM, palladium-103, dosimetric parameters, dose rate constants
  • 相关文献

参考文献10

  • 1Rivard M J,Coursey B M,DeWerd L A, et al.2004 Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations[].Medical Physics.2004
  • 2Ali S,Meigooni S B,Awan N S, et al.Updated Solid WaterTM to water conversion factors for 125I and 103Pd brachytherapy sources[].Medical Physics.2006
  • 3Murphy M K,Piper R K,Greenwood L R, et al.Evaluation of the new cesium-131 seed for use in low-energy X-ray brachytherapy[].Medical Physics.2004
  • 4Meigooni A S,Dini S A,Awan S B, et al.Theoretical and experi- mental determination of dosimetric characteristics for ADVANTAGE Pd-103 brachytherapy source[].Applied Radiation and Isotopes.2006
  • 5Rivard M J.A discretized approach to determining TG-43 brach- therapy dosimetry parameters: Case study using Monte Carlo calcu- lations for the MED3633 103Pd source[].Applied Radiation and Isotopes.2001
  • 6Reniers B,Vynckier S,Scalliet P.Dosimetric study of a new palla- dium seed[].Applied Radiation and Isotopes.2002
  • 7Wallace R E.Model 3500 125I brachytherapy source dosimetric characterization[].Applied Radiation and Isotopes.2002
  • 8X-5 Monte Carlo Team.MCNP—A General Monte Carlo N-ParticleTransport Code. Ver. 5[]..2003
  • 9RSICC Computer code collection.Monte Carlo N-particle Transport Code System[]..2000
  • 10Wang R,Sloboda R S.Monte Carlo dose parameters of the Brachy Seed model LS-1 brachytherapy source[].Applied Radiation and Isotopes.2002

同被引文献13

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部