期刊文献+

无交流电流传感器的三相PWM整流器控制策略 被引量:1

AC current sensorless control of three-phase PWM rectifier
下载PDF
导出
摘要 提出了一种无交流电流传感器的PWM整流器控制方法,交流电流通过检测开关状态和直流电流进行电流重构获得,进行最小调制时间补偿控制以确保正确重构交流电流。整流器采用空间矢量PWM电流控制,控制系统采用电压外环和电流内环的双闭环PI控制结构。研究表明,该控制策略有良好的控制性能,可以实现网侧电流正弦化和单位功率因数运行。 In this paper, an AC current sensorless control strategy of three-phase PWM rectifier is proposed. A method for reconstructing the AC current from the DC-link current and switch states is given. A method of modifying the switching state of PWM rectifier is given when the input currents cannot be reconstructed. SVPWM is used for controlling the rectifier's current, and the control system includes two PI controllers which are used to regulate the AC current and DC voltage. The feasibility of this strategy has been confirmed through computer simulations.
出处 《继电器》 CSCD 北大核心 2008年第8期68-72,共5页 Relay
关键词 整流器 无交流电流传感器 电流重构 rectifier AC current sensorless current reconstruction
  • 相关文献

参考文献8

  • 1Wu R, Dewan S B, Slemon G R. Analysis of An AC to DC Voltage Source Converter Using PWM with Phase and Amplitude Control [J]. IEEE Trans Ind Appl, 199t, 27: 355-364.
  • 2Lee Dong-Choon, Lim Dea-Sik. AC Voltage and Current Sensorless Control of Three-Phase PWM Rectifiers[J]. IEEE Trans on Power Electron, 2002, 17: 883-890.
  • 3Lee Woo-Cheol, Hyun Dong-Seok, Lee Taeck-Kie. A Novel Control Method for Three-Phase PWM Rectifiers Using a Single Current Sensor[J]. IEEE Trans on Power Electron, 2000,15: 860-870.
  • 4Pan C T. Modeling and Analysis of a Three Phase PWM AC-DC Converter Without Current Sensor[J]. IEEE Proceedings-B, 1993,140: 201-208.
  • 5Bhowmik A,van Zyl A, Spee R,et al. Sensorless Current Control for Active Rectifiers[J]. IEEE Trans on Ind Appl, 1997,33:765-773.
  • 6张恩,廖晓钟.无电流传感器三相PWM整流器控制策略[J].电工技术学报,2004,19(11):42-45. 被引量:8
  • 7张笑微,杨青.无电流传感器的PWM整流器的仿真研究[J].电力电子技术,2004,38(6):69-71. 被引量:6
  • 8李时杰,李耀华.PWM整流器无电流传感器前馈控制策略的研究[J].电气传动,2006,36(12):43-46. 被引量:4

二级参考文献11

  • 1钟炎平,沈颂华.PWM整流器的一种快速电流控制方法[J].中国电机工程学报,2005,25(12):52-56. 被引量:60
  • 2[2]Toshihiko Noguchi,Hiroaki Tomiki, Seiji Kondo,et al. Direct power control of PWM converter without power-source voltage sesnsors. IEEE Trans. on Industry Applications, 1998, 34(3):473~479
  • 3[3]Malinowski M, Kazmierkowski M P. Simulation study of virtual flux based direct power control for three-phase PWM rectifiers. Industrial Electronics Society, of 26th Annual Confjerence of the IEEE, 2000, 4(10):22~28
  • 4[4]Steffan Hansen, Mariusz Malinowski, Frede Blaabjerg, et al. Sensorless control strategies for PWM rectifier. Applied Power Electronics Conference and Exposition, of 15th IEEE APEC, 2000, 2(2):6~10
  • 5[5]Su Chen, Joos G. Direct power control of three phase active filter with minimum energy storage components. Applied Power Electronics Conference and Exposition, of 16th IEEE APEC, 2001, 1(3):4~8
  • 6Wernekinck E,Kawamura A,Hoft R.A High Frequency AC-DC Converter with Unity Power and Minimum Harmonic Distortion [A].IEEE Power Electronics Specialists Conference[C].1987, 264-270.
  • 7Wu R, Dewan S B, Slemon G R.Analysis of an ac-todc Voltage Source Converter Using PWM with Phase and Amplitude Control [J].IEEE Trans. on IA,1991,27:355-363.
  • 8Mazumder S,Nayfeh A H,Borojevic D.New Sensorless Control of Three-phase Bi-directional Converter Using Space-vector Modulation.0-7803-5421-4/99[Z].1999.
  • 9Nargari.Performance Investigation of a Current-controlled Voltage-regulated PWM Rectifier in Rotating and Stationary Frames.IEEE Trans.Ind.Electron,1993,42(4):396~401
  • 10Jong.Fast Current Controller in Three-phase AC/DC Boost Converter Using d-q Axis Crosscoupling.IEEE Trans.Power Electronics,1998,13(1):179~185

共引文献14

同被引文献11

  • 1张恩,廖晓钟.无电流传感器三相PWM整流器控制策略[J].电工技术学报,2004,19(11):42-45. 被引量:8
  • 2BOYS J T. Novel current sensor for PWM AC drives[ J ]. Electric" Power Applications , 1988, 135(1) : 27 -32.
  • 33 phase current measurements using a single line resistor on TM320F240 [ EB/OL ]. http://www. ti. com/sc/docs/psheels/abstract/apps/bpra077, html, 2009 -03 - 10.
  • 4KIM H R, JAHNS T M. Phase current reconstruction for ac motor drives using adc link single current sensor and measurement voltage vectors[J]. IEEE Trans on Power Electron, 2006, 21 (5): 1413 - 1419.
  • 5LEE W C, HYUN D S, LEE T K. A novel control method for three-phase PWM rectifiers using a single current sensor [ J ]. IEEE Trans on Power Electron, 2000, 15(5): 861 -870.
  • 6YING L, ERTUGRUL N. A novel estimation of phase currents from dc link for permanent magnet ac motors [ C ]//TENCON 2001. Singapore: IEEE Press, 2001, 2:606 -612.
  • 7WOLBANK T M, MACHEINER P. An improved observer-based current controller for inverter fed ac machines with single dc-link current measurement[C]//PESC 2002. Cairns, North Queensland, Australia: IEEE Press, 2002(2) : 1003 - 1008.
  • 8WOLBANK T M, MACHEINER P E. Cun'ent-controller with single DC link currenl measurement for inverter-fed ac machines based on an improved observer-structure[ J ]. IEEE Trans on Power Electronics, 2004, 19(6): 1562-1567.
  • 9JOO H G, YOUN M J, SHIN H B. Estimation of phase currents from a dc-link current sensor using space vector PWM method [ J ]. Electric Machines and Power Systems, 2000, 28:1053 - 1069.
  • 10MOYNIHAN J F, KAVANAGH R C, EGAN M G, et al. Indirect phase current detection for field oriented control of a permanent magnet synchronous motor drive [ C ]//EPE 1991. Firenze : [s.n.], 1991: 3-6.

引证文献1