摘要
TU+PJE是由于SDH网络时钟不同步引起,通过对其产生的机理进行认真分析,从检测点沿业务传输方向向上查找,然后找到网络中不同步的站点。检测到是由于的时钟板故障,提供的时钟源质量不好,导致无法锁定跟随的时钟源,进而排除故障。
TU+ PJE is as result of asynchronous SDH Network. Through careful analyzing the causation of TU + PJE, lookup upward direction from the test point along the transmission, then found asynchronous NE (Network Element) in the Network. Because of the clock module' s fault , it lead to the failure which can not lock the clock source, thereby troubleshooting.
出处
《广西通信技术》
2008年第1期53-54,共2页
Guangxi Communication Technology
关键词
TU+PJE
SDH
网元
时钟源
TU + PJE, Synchronous Digital Hierarchy (SDH) , Network Element , Clock source