摘要
分析了铁道客车空调压缩机绝缘不良的原因,提出了处理方法及改进建议。
The causes to bad insulation in air-conditioned compressors for railway passenger cars are analyzed.The method for disposition and suggestions for improvement are given.
出处
《铁道车辆》
北大核心
2008年第5期42-43,共2页
Rolling Stock
关键词
压缩机
绝缘
分析
compressor
insulation
analysis