期刊文献+

三点弯曲裂纹张开柔度的实验研究

Experimental study of crack opening compliance of a three-point bending beam
下载PDF
导出
摘要 运用裂纹张开柔度法对ASTME399-1990和GB/T4161-1984中三点弯曲试样测试断裂韧度KIC中的线弹性加载特性进行实验研究,结合疲劳裂纹扩展过程,得出GB/T4161对试样加载平行度要求过严的结论,提出平行度放宽到0.05 W的范围。 The linear elastic loading characteristics of the three - point bend specimen in the ASTM E399 - 1990 and GB/T4161 - 1984 has been tested in the laboratory by means of crack mouth opening compliance method during testing fracture toughness KIC and in combination with the study on the process of proliferation of the fatigue fracture it's concluded that the constrain condition of contact face provided by GB/T4161 is too severe. An operative suggestion to relieve the constrain condition to certain extent is also presented.
机构地区 武钢研究院
出处 《武钢技术》 CAS 2008年第2期1-3,15,共4页 Wisco Technology
关键词 三点弯曲 裂纹 断裂韧度 线弹性加载 three-point bending crack fracture toughness linear-elastic loading
  • 相关文献

参考文献3

  • 1STM Standard E399-90.Standard test method for plane strain fracture toughness of metallic materials[S].Annual book of ASTM Standards,Vol.03.01.ASTM International; 2002.
  • 2金属材料平面应变断裂韧度KIC试验方法.GB/T 4161-1984[S].国家质量技术监督局,1984.
  • 3Wu S.X..Crack length calculation formula for three-point bend specimen[J].Int.J.Fract,1984,24:33-35.