期刊文献+

外管极式静电除尘器故障分析及处理

Fault Analysis and Disposal of Outer Pipe Pole Electrostatic Precipitator
下载PDF
导出
摘要 介绍了GDⅢ型外管极式静电除尘器的工作原理,重点阐述了外管极式静电除尘器常见故障现象,并指出了故障的分析与处理方法。 The principle of GD Ⅲ outer pipe pole electrostatic precipitator is introduced briefly, the common faults of outer pipe pole electrostatic precipitator are set forth in detail ,and the analysis and disposal of faults are put forward.
出处 《现代制造技术与装备》 2008年第2期42-44,共3页 Modern Manufacturing Technology and Equipment
关键词 静电除尘器 故障 分析与处理 electrostatic precipitator, fault, analysis and disposal
  • 相关文献

参考文献2

二级参考文献9

  • 1[3]姚宇飞.现代锅炉除尘设备[R].哈尔滨:哈尔滨工业大学燃烧工程研究所,2004.
  • 2[4]唐国山.工业电除尘器应用技术[M].北京:化学工业出版社,2004.
  • 3[5]Shafer Jon.Dust collection basics[M].Woodstock International Incorporated Publisher,1991.
  • 4[6]Rosentrater K A.Laboratory analysis of an electrostatic dust collection system[M].The CIGR Journal of Scientific Research and Development Publisher,2004.
  • 5Mizuno A. Electrostatic precipitation [ J ]. IEEE Transaetions on Dielectrics and Electrical Insulation,2000,7(5) :615 - 624.
  • 6Snyder TR, Bush PV, Pontius DH. Laboratory analysis of back-corona discharge[J], Journal of Electrostatics, 1987,19(1) : 101 - 1141.
  • 7Tawfic MM, Morcos MM. Proay application for locating faults on loop systems[ J ], IEEE Power Engineering Review, 2001,21 ( 8 ) : 41 - 43.
  • 8许德玄,孙大伟.V型极板抑制高比电阻粉尘反电晕的研究[J].环境科学学报,1998,18(5):522-525. 被引量:5
  • 9王洋,王宁会.基于Prony算法的静电除尘器放电信号分析[J].中国电机工程学报,2003,23(1):141-144. 被引量:21