期刊文献+

不同碘浓度对比剂在肾脏MSCT增强扫描中的作用对比 被引量:6

Effect of Different Lodine Concentration of Contrast Media in the Enhancement of kidney with Multislice CT
下载PDF
导出
摘要 目的:探讨300mgI/ml对比剂与400mgI/ml对比荆对肾脏MSCT多期增强扫描的强化作用。方法:将40例疑肾脏病变的患者随机分成两组,每组20例,分别行肾脏平扫及给予碘必乐300(300mgI/ml)与碘迈伦400(400mgI/ml)的多期增强MSCT扫描。在对比剂开始注射后18s、30s、80s、3~5min扫描。测量各期增强扫描腹主动脉、双肾动脉、双肾静脉、双肾皮质、双肾髓质、双肾盂、肾脏病变的CT强化值。观察上述结构的强化情况。结果:使用400mgI/ml对比剂组在18s与30s采集,所检测的血管与肾各结构强化均值与300mgI/ml对比剂组相比,差异有显著性意义(P〈0.01),80s采集,肾动脉、肾静明炙肾髓质强化均值与300mgI/ml对比剂组相比,差异有显著性意义(P〈0.01),3~5min采集,肾静脉与肾盂强化均值与300mgI/ml对比剂组相比,差异有显著性意义(P〈0.01)。结论:高碘浓度对比剂对肾血管的显示优于标准碘浓度对比剂,并可降低对比剂用量。肾脏MSCT高碘浓度对比剂增强扫描在对比剂开始注射后30s与延时3~5min采集较合理。 Objective:To study the effect of contrast enhancement of kidney with contrast media containing iodine for 300 or 400mgI/ml in MSCT. Methods:Totally 40 patients with suspected kidney diseases were randomly assigned into two groups,20 patients for each group. Group A received contrast media containing 300mg iodine/ml (1. 5ml/kg of body weight) ,whereas group B received the same agent yet containing 400mg iodine/ml (1ml/kg of body weight), the injection rate was 3ml/s. MSCT was undertaken at 18s,30s,80s and 3-5min after starting of injection. The CT value (HU) of abdominal aorta, renal arteries, veins, cortex, medulla and renal pelvis of bilateral kidney as well as renal lesion were measured to observe the degree of enhancement in different phases. Results:For group B,at 18s and 30s,high iodine concentration contrast led to greater enhancement in blood vessels and normal renal structures than group A, with significant statistical difference (P〈0.01). At 80s, high iodine concentration used in group B led to greater enhancement in renal arteries, renal veins, renal medulla than group A, with significant statistical difference (P〈0.01). At 3 to 5min,enhancement was greater in renal veins and renal pelvis,with significant statistical difference as well (P〈0.01). Conclusion: High iodine concentration contrast media improves contrast enhancement of renal vessels,the overall volume of contrast media used could be reduced. For MSCT of kidney,it is reasonable to use high iodine concentration contrast media,and to perform the CT scanning at 30s and 3min to 5min after starting of injection.
出处 《放射学实践》 2008年第5期534-538,共5页 Radiologic Practice
关键词 对比剂 体层摄影术 X线计算机 对比研究 肾脏 Contrast media Tomography,X-ray computer Comparative studies Kidney
  • 相关文献

参考文献11

  • 1Kocakoc E,Bhatt S,Dogra VS.Renal Multidector Row CT[J].Radiol Clin North Am,2005,43(6):1021-1047.
  • 2周建军,丁建国,周康荣,陈祖望.肾细胞癌多层螺旋CT多期扫描:评价皮髓交界早期和皮髓交界期的价值[J].临床放射学杂志,2006,25(4):337-340. 被引量:19
  • 3Anderson EM,Murphy R,Rennie AT,et al.Multidetector Computed Tomography Urography (MDCTU) for Diagnosing Urothelial Malignancy[J].Clin Radiol,2007,62(4):324 -332.
  • 4Itoh S,Ikeda M,Achiwa M,et al.Multiphase Contrast-enhanced CT of the Liver with a Multislice CT Scanner:Effects of Iodine Concentration and Delivery Rate[J].Radiat Med,2005,23(1):61-69.
  • 5Fenchel S,Fleeter TR,Aschoff AJ,et al.Effect of Iodine Concentration of Contrast Media on Contrast Enhancement in Multislice CT of the Pancreas[J].Brit J Radio,2004,77(10):821-830.
  • 6Furuta A,Ito K,Fujita T,et al.Hepatic Enhancement in Multiphasic Contrast-enhanced MDCT:Comparison of High-and Low-iodine-concentration Contrast Medium in Same Patients with Chronic Liver Disease[J].Am J Roentgenol,2004,183(1):157-162.
  • 7Loubeyre P,Debard I,Nemoz C,et al.Using Thoracic Helical CT to Assess Iodine Concentration in a Small Volume of Nonionic Contrast Medium During Vascular Opacification:a Prospective Study[J].Am J Roentgenol,2000,174(3):783-787.
  • 8Masui T,Katayama M,Kobayashi S,et al.Intravenous Injection of High and Medium Concentrations of Computed Tomography Contrast Media and Related Heat Sensation,Local Pain,and Adverse Reactions[J].J Comput Assist Tomogr,2005,29(5):704-708.
  • 9Nagamoto M,Gomi T,Terada H,et al.Evaluation of the Acute Adverse Reaction of Contrast Medium with High and Moderate Iodine Concentration in Patients Undergoing Computed Tomography[J].Radiat Med,2006,24(10):669-674.
  • 10Thomsen HS,Morcos SK,Webb JAW and Members of Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR).Contrast Media Induced Nephrotoxicity:a Consensus Report[J].Eur Radiol,1999,9():1602-1613.

二级参考文献11

  • 1Hernandez Jover D,de la Torre Holguera P,Alberola Bou J,et al.Small renal mass.Diagnostic management.Arch Esp Urol.2001,54:593.
  • 2Apaydin FD,Ozer C,Duce MN,et al.Comparison of reliabilities of the delayed images of helical renal CT in detecting small renal masses.Clin Imaging.2003,27:112.
  • 3Urban BA.The small renal mass:what is the role of multiphasic helical scanning? Radiology,1997,202:22.
  • 4Birnbaum BA,Jacobs JE,Ramchandani P.Multiphasic renal CT:comparison of renal mass enhancement during the corticomedullary and nephrographic phase.Radiology,1996,200:753.
  • 5Yuh BI,Cohan RH.Different phases of renal enhancement:role in detecting and characterizing renal masses during helical CT.AJR,1999,173:747.
  • 6Cohan RH,Sherman LS,Korobkin M,et al.Renal masses:assessment of corticomedully-phase and nephrographic-phase CT scans.Radiology,1995,196:445.
  • 7Szolar DH,Kammerhuber F,Altziebler S,et al.Multiphasic helical CT of the kidney:increased conspicuity for detection and characterization of small renal masses.Radiology,1997,202:211.
  • 8Kopka L,Fischer U,Zoeller G,et al.Dual phase helical CT of the kidney:value of the corticomedullary and nephrographic phase for evaluation of renal lesions and preoperative staging of renal cell carcinoma.AJR,1997,169:1573.
  • 9Zeman RK,Zeiberg A,Hayes WS,et al.Helical CT of renal masses:the value of delayed scans.AJR,1996,167:771.
  • 10Dahlman P,Semenas E,Brekkan E,et al.Detection and characterisation of renal lesions by multiphasic helical CT.Acta Radiol,2000,41:361.

共引文献18

同被引文献83

  • 1缪熙音,陈刚,陈文芳,陆海峰,张利军,曾良斌,陆秀良,周建军.64排螺旋CT胰周血管CT成像:不同浓度对比剂的对照研究[J].中国临床医学影像杂志,2010,21(11):830-832. 被引量:11
  • 2黄怀钱.多层螺旋CT在肾癌诊断中的应用——附42例分析[J].中国CT和MRI杂志,2006,4(2):53-55. 被引量:6
  • 3公佩友,耿军祖,邹振兴,王福江.肾动脉变异的16层螺旋CT表现[J].泰山医学院学报,2006,27(4):303-306. 被引量:21
  • 4Kuhn E,De Anda J,Manoni S,潘敏鸿(摘译),饶秋(摘译),周晓军(审校).伴有明显血管平滑肌瘤样增生的肾细胞癌[J].临床与实验病理学杂志,2006,22(6):719-719. 被引量:7
  • 5Ozkan U, Oguzkurt L, Tercan F, et al. Renal artery origins and variations: angiographic evaluation of 855 consecutive patients. Diagn lnterv Radiol, 2006,12(4) :183-186.
  • 6Dhar P, Lal K. Main and accessory renal arteries-a morphological study. Ital J Anat Embryol, 2005,110(2):101-110.
  • 7Tran T, Heneghan JP, Paulson EK. Preoperative evaluation of potential renal donors using multideteetor CT. Abdom Imaging, 2002,27(6) :620-625.
  • 8Kok NF, Dols LF, Hunink MG, et al. Complex vascular anatomy in live kidney donation: imaging and consequences for clinical outcome. Transplantation, 2008,85(12) : 1760-1765.
  • 9Saba L, Sanfilippo R, Montisci R, et al. Accessory renal artery stenosis and hypertension: are these correlated? Evaluation using muhidetector-row computed tomographic angiography. Acta Radiol, 2008,49(3) :278-284.
  • 10Gupta A, Tello R. Accessory renal arteries are not related to hypertension risk: a review of MR angiography data. AJR Am J Roentgenol, 2004,182(6):1521-1524.

引证文献6

二级引证文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部