期刊文献+

硝酸甘油致不良反应文献分析 被引量:5

Literature Analysis of Adverse Drug Reaction Induced by Nitroglycerin
下载PDF
导出
摘要 目的探讨硝酸甘油所致不良反应的一般规律及其特点,为临床合理用药提供参考。方法对国内各种期刊报道的81例硝酸甘油不良反应的病例进行统计分析。结果硝酸甘油所致的不良反应l临床表现复杂多样,主要表现为心血管系统的不良反应(56.79%),其次是过敏反应(13.58%)。结论临床应重视硝酸甘油的不良反应,特别是心血管系统不良反应,而心脏性猝死应是关注的重点。 Objective To study the general pattern and characteristics of adverse drug reactions induced by Nitroglycerin and to offer reference for clinical reasonable medication. Methods A statistical analysis was conducted for 81 ADR cases induced by Nitroglycerin reported by domestic journals. Results The clinical manifestations of ADRS induced by Nitroglycerin were manifold and the first main ADRS was damages of cardiovascular system (56.79%), and the second was anaphylactic response ( 13.58% ). Conclusion Great importance should be attached to ADRS of Nitroglycerin, especially sudden cardiac death.
出处 《预防医学情报杂志》 CAS 2008年第5期372-374,共3页 Journal of Preventive Medicine Information
关键词 硝酸甘油 不良反应 文献分析 Nitroglycerin ADR Literature analysis
  • 相关文献

参考文献15

二级参考文献1

  • 1国家药典委员会.临床用药须知.北京:化学工业出版社,1996.205.

共引文献12

同被引文献43

  • 1何珍,万业达,付菲,张瑞禄,张琳,李宝玖,齐扬.舌下含服硝酸甘油对冠状动脉CT成像质量影响的研究[J].临床放射学杂志,2006,25(8):731-734. 被引量:13
  • 2朱巧洪,曾庆思,孙翀鹏,林翰菲,岑人丽,张超亮,刘莉.服用硝酸甘油对多层螺旋CT冠状动脉成像的影响[J].中华放射学杂志,2007,41(8):809-812. 被引量:24
  • 3Hackenbroch M, Meyer C, Schmiedel A, et al. The value of applyhag nitroglycerin in 3D coronary .MR angiographie with real-time navigation technique [J]. Rofo, 2004, 176(8): 1133-1141.
  • 4Schussler JM, Graybum PA. Non-invasive coronary angiography with multislice computed tomography [J]. Heart, 2007, 29(3): 290-297.
  • 5Dewey M, Laule M, Krug L, et al. Multisegment and hualfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses [J]. Invest Radiol, 2004, 39: 223-229.
  • 6Ropers D, Baum U, PohIe K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J]. Circulation, 2003, 107(5): 664-666.
  • 7Raft GL, Gallagher MJ, O' Neill WWW, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography [J]. J Am Coil Cardiol, 2005, 46: 552-557.
  • 8Achenbach S, Ropers D, Pohle FK, et al. Detection of coronary artery stenoses using multi-detector CT with 16x0.75 collimation and 375 ms rotation [J]. Eur Heart J, 2005, 26(19): 1978-1986.
  • 9Ohnesorge B, Flobx T, Becker C, et al. Cardiac imageing by means of electrocardiographieally gated multisection spiral CT: Initial experience [J]. Radiology, 2000, 217(2): 564-571.
  • 10Jost S, Rafflenbeul W, Reil GH, et al. Reproducible uniform coro nary vasomotor tone with nitrocompounds; Prerequisite of quantita- tive coronary angiographic trials [J]. Cathet Cardiovasc Diagn, 1990, 20(3): 168-173.

引证文献5

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部