摘要 文章提出并阐述了一种用于在电信、移动通讯等行业的机房中,应用AVR单片机及其控制电路,结合485读表技术,来实现对基站中电度表DTS118电量读取的方法。 In the paper, a method used in equipment rooms of industries such as telecommunication, mobile communication was presented and expatiated, for which AVR MCU and its control circuit was applied and 485 meter reading technology was referenced. The method carried out the coulometry of DTS118 in the mobile stations.
出处 《东北农业大学学报》 CAS CSCD 2008年第4期28-30,共3页 Journal of Northeast Agricultural University
关键词 基站动力环境 AVR单片机 DTS118 RS-485 power and environment in mobile stations AVRMCU DTS118 RS-485
  • 相关文献

参考文献3

共引文献1

同被引文献6

  • 1宋守国.基于无线GPRS/SMS方式的移动基站动力环境监控系统[J].电信工程技术与标准化,2007,20(6):69-72. 被引量:8
  • 2Mazurek B,Moron Let aLElectric insulation for energy-saving equipment.PADM2000 Proceedings of the 6th International Conference.Page(s): 607 - 610 vol.2000.
  • 3Van Gorp.Maximizing energy savings with enterprise energy management systems.Pulp and Paper Industry Technical Conference, Page(s): 175 - 181.2004.
  • 4Yongping Yang~Ningling WangResearch on the Energy- Saving Management System of Power Generation Groups and Key Supporting Technologies.Power and Energy Engineering Conference, 2009.
  • 5Groza V.,Giurgiu V..Energy savings techniques in ventilation processes with fans operating at variable load.Electrical Power & Energy Conference (EPEC), 2009 IEEE.
  • 6王茜.移动基站动力及环境设备集中监控系统的设计[J].计算机应用,2002,22(3):56-57. 被引量:7