摘要
研究了核电厂废物桶中放射性核素活度测量校正算法,并用计算机以1:2模型模拟核电厂实际废物桶来验证所研究的算法。结果表明:与现有的算法相比,本研究的算法误差较小。而且算法的实际应用性强,能很好满足层析γ扫描(Tomographic gamma scanning,TGS)技术装置的要求。
In this paper, the algorithm for calibrating mdionuclide activity of waste barrels from a nuclear power plant is studied. A simulations to validate the algorithm was done on a model of 1:2 ratio to an actual waste barrel at a nuclear power plant. The results indicate that the image reconstruction errors are smaller than other algorithms. Further more, this method, with strong practicability, can well meet the requirements of TGS device.
出处
《核技术》
EI
CAS
CSCD
北大核心
2008年第5期396-400,共5页
Nuclear Techniques
基金
国家自然科学基金(10675084)资助
关键词
层析γ扫描
线性衰减系数
蒙特卡罗
透射图像重建
Tomographic gamma scanning, Linear attenuation coefficient, Monte-carlo, Transmission image reconstruction