期刊文献+

椭圆弯晶谱仪波长判读误差分析 被引量:1

ANALYSIS OF WAVELENGTH ERRORS IN ELLIPTICAL SPECTROMETER
下载PDF
导出
摘要 把影响椭圆弯晶谱仪波长判读误差的因素分为两种:一种是未通过椭圆前焦点的射线被理想椭圆晶面衍射时形成的误差;另一种是只考虑晶体为非理想椭圆晶面形成的误差。分别对这两种模型进行了分析,并通过数值计算给出狭缝对椭圆弯晶谱仪波长判读误差的影响关系。模拟的数据与其他人的实验结果吻合较好。 The errors of wavelength in elliptical crystal spectrometer are divided into two models:1) The target center is not on the focus of the ellipsoid, the target size can not be ignored, and the background scatters from any directons; 2) The X-ray is reflected from irregular crystal surface, which is not an ideal ellipsoid. The analysis of these two models are gvien and the relation between the wavelength errors and the aperture slit width are presented with digital calculation. The calculation data are agreeable to the experiments.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 1997年第4期623-626,共4页 High Power Laser and Particle Beams
关键词 弯晶谱仪 误差分析 波长判断 等离子体诊断 crystal spectrometer, error analysis
  • 相关文献

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;