摘要
用自制的实验室快速渗滤系统模拟反应器对生活污水进行处理.研究结果表明,此套实验室模拟快渗处理生活污水系统对CODCr、TN、TP去除效果良好,对CODCr的去除率最大值为95.4%,TN为74.7%,TP为83.5%.在布水4 d后,出水CODCr,TN和TP质量浓度分别稳定在20 mg/L,20 mg/L和1.5 mg/L以下.
This paper describes a simulated study on the sewage treatment for school water stations. A constructed rapid infiltration system was made in this laboratory. The results show that this set of laboratory simulation of rapid infiltration on the treatment of domestic sewage system CODcr, TN, TP good removal efficiency, the removal of the maximum CODcr for 95.4%, TN for 74.7%, TP for 83.5 %. In continuous water four days later, the effluent CODcr, TN and TP are steady at 20 mg/L and 20 mg/L and 1.5 mg/L following.
出处
《北京工商大学学报(自然科学版)》
CAS
2008年第3期1-3,8,共4页
Journal of Beijing Technology and Business University:Natural Science Edition
基金
国家自然科学基金资助项目(50779001)
北京市2007年度学术创新团队资金资助项目
关键词
人工快渗系统
生活污水
去除率
constructed rapid infiltration system
sewage
removal