摘要
对采用新型沸腾传热强化措施的工业用板翅式冷凝蒸发器单元试样的传热特性进行了实验研究,实验结果表明:本文的实验单元与现行的6000m3/h空分装置的板翅式主冷凝蒸发器相比,换热系数提高了近一倍,传热温差下降了40%~50%。
An experimental study on the heat transfer characteristics is carried out in a platefin condenserboiler unit which is provided with microfilm boiling heat transfer enhancement method. The experimental rsults show that compared to the existing platefin condenserboilers in a 6000m3/h air separation unit, the heat transfer coefficient is almost increased more than one time and the heat transfer temperature difference is less than one half of it.
出处
《低温工程》
CAS
CSCD
北大核心
1997年第6期35-39,共5页
Cryogenics
关键词
传热
板翅式
换热器
两相流
热交换
Heat Transfer
Platefin Heatexchangers
Twophase Flow