摘要 采用离子色谱—电感耦合等离子体质谱联用法分析了水中溴酸根和溴离子的含量,对流动相、进样量和干扰因素进行了研究。试验表明,以IonPacAS14柱为分离柱、30mmol/L的(NH4)2CO3为淋洗液,当流速为1mL/min、进样量为1mL时,该方法对BrO3-和Br-的检测限(MDL)分别为0.12、0.21μg/L,回收率分别为96.0%、100.8%,相对标准偏差分别为3.71%、2.72%。 Ion chromatography/inductively coupled plasma mass spectrometry (ICP-MS) was used to analyze BrO3^- and Br^- in water, and the flow phase, sample injection volume and disturbance factors were studied. The test shows that when IonPac AS14 analytical column, 30 mmol/L (NH4 )2CO3 eluent, 1 mL/min flow rate and 1 mL sample injection volume are used, the method detection limits of BrO3^- and Brare 0.12 μg/L and 0.21 μg/L, the recoveries are 96.0% and 100.8% , and the RSDs are 3.71% and 2.72% respectively.
出处 《中国给水排水》 CAS CSCD 北大核心 2008年第10期82-84,共3页 China Water & Wastewater
关键词 离子色谱 电感耦合等离子体质谱 溴酸根 溴离子 ion chromatography inductively coupled plasma mass spectrometry bromate bromide ion
  • 相关文献

参考文献6

  • 1Divjak B, Novic M, Goessler W. Determination of bromide, bromate and other anions with ion chromatography and an inductively coupled plasma mass spectrometer as element-specific detector[ J]. J Chromatogr A, 1999,862 ( 1 ) :39 -47.
  • 2苏宇亮,冯兆敏,胡克武,曾锦明.离子色谱法测定水中的卤代乙酸和卤素含氧酸[J].中国给水排水,2006,22(12):86-88. 被引量:10
  • 3US EPA Method 317.0, Determination of Inorganic Oxyhalide Disinfection By-products in Drinking Water Using Ion Chromatography with the Addition of a Postcolumn Reagent for Trace Bromate Analysis[ S].
  • 4沈金灿,荆淼,陈登云,沈阳,王小如,Frank S. C. Lee.离子色谱电感耦合等离子体质谱联用法测定水中痕量BrO_3^-及Br^-[J].分析化学,2005,33(7):993-995. 被引量:32
  • 5US EPA Method 321. 8, Determination of Bromate in Drinking Waters by in Chromatography Inductively Coupled Plasma-Mass Spectrometry[ S].
  • 6Nowak M, Seubert A. Ultra-trace determination of bromate in drinking waters by means of microbore column ion chromatography and on-line coupling with inductively coupled plasma mass spectrometry [ J ]. Anal Chim Acta, 1998,359 ( 1 - 2) : 193 - 204.

二级参考文献13

  • 1Haag W R, Holgne J. Environ. Sci. Technol., 1983, 17: 261-267
  • 2US EPA. Determination of Bromate in Drinking Waters by in Chromatography Inductively Coupled Plasma-Mass Spectrometry, Washington DC: USEPA, 1997: Method 321.8
  • 3Creed J T, Magnuson M L, Pfaff J D, Brockhoff C. J. Chromatogr. A, 1996, 753: 261-267
  • 4Nowak M, Seubert A. Anal. Chim. Acta, 1998, 359: 193-204
  • 5QiZhuhua(齐竹华) QuFeng(屈峰) LiuKena(刘克纳) MouShifen(牟世芬).Chinese Environment Chemical(环境化学),1998,17(6):601-605.
  • 6Stalberg O, Sander K, Griend C S. J. Chromatogr. A, 2002, 977: 265-275
  • 7Divjak B, Novic M, Goessler W. J. Chromatogr. A, 1999, 862: 39-47
  • 8张金松,范晓军.国际饮用水水质标准[M].北京:中国建筑工业出版社,2001.
  • 9CJ/T 206-2005,城市供水水质标准[S].
  • 10HPLC高灵敏度分析水中的溴酸盐[J].环境化学,2000,19(3):289-290. 被引量:3