现有钢筋混凝土框架结构中梁、柱、节点因设计不当或施工事故,发生梁、柱、节点不能满足强柱弱梁、强节点弱构件的抗震设计原则,针对强柱弱梁、梁弱弯弱剪、梁纵筋锚固不足等4个节点试件进行了低周反复加荷对比试验,从破坏过程分析了梁、柱、节点核心区不同粘钢加固方案的效果。试验结果表明:粘钢加固对提高构件强度、改变框架破坏机制及增加变形能力具有良好的效果。并全面地分析了试件加固方案的优劣,初步给出了粘钢加固节点的构造措施和更合理的加固方法。
, Because of design or constructional accidents of beamcolumn nodes in present reinforced concrete frame structures,cases that beamcolumn nodes can′t satisfy the seismic design principles of strongcolumn weakbeam and strongnode weakmember occur,comparative tests of lowfregnency cyclic reverse loading on four nodal members which are strongcolumnweakbeam,have weakbendingandshear beams,and have beams with insufficiently anchored longitudinal bars are given in the paper.Effects on beamcolumn nodal core sections of various stickysteel reinforcement methods are investigated from failure mechanisms of different members. The experimental results indicate that stickysteel reinforcement is effective in improving failure mechanism of frame and increasing deformation capacity.
出处
《工业建筑》
CSCD
北大核心
1997年第10期15-19,共5页
Industrial Construction
关键词
钢筋混凝土结构
框架
粘结钢板
破坏
节点