期刊文献+

基于广义Gibbs先验的低剂量X-CT优质重建研究 被引量:9

Generalized Gibbs prior based high quality low-dose X-CT reconstruction
下载PDF
导出
摘要 为获取低剂量条件下X-CT的优质重建,提出基于广义Gibbs先验的低剂量X-CT重建算法。新算法首先对投影数据进行统计建模,其后采用Bayesian最大后验估计方法,将投影数据中非局部的先验信息加诸于该数据的恢复中,达到抑制噪声的效果,最后仍采用经典的滤波反投影方法对恢复后的投影数据进行解释CT重建。文中将非局部先验称为广义Gibbs先验,其原因在于该先验具有传统Gibbs先验形式的同时,可以通过选择较大邻域和自适应的加权方式充分利用投影数据的全局信息进行数据恢复。通过与已有算法的对比实验,表明该文提出的基于广义Gibbs先验的低剂量X-CT重建算法在降低噪声效果和保持边缘方面具有较好的表现。 In order to obtain the high quality reconstruction images for low-dose X-CT,we proposed a new generalized Gibbs prior based low-dose X-CT reconstruction method.First,X-CT projection data was modeled as a statistics process.Then based on Bayesian maximum posteriori estimation method,we designed a novel Gibbs prior named as generalized Gibbs prior,which exploited nonlocal information of the data to suppress noise.Last,we used the filtered back-projection method to finish the final CT reconstruction.The reason for the name of generalized Gibbs prior is that it has been shown to suppress noise effectively while capturing sharp edges without oscillations through the selection of larger neighborhood and adaptive weight form with global information of an image.Comparisons between the new method and other models clearly demonstrate that the proposed generalized Gibbs prior based low-dose X-CT reconstruction method performs better in lowering the noise and preserving the edge and detail in the image.
出处 《计算机工程与应用》 CSCD 北大核心 2008年第16期4-6,93,共4页 Computer Engineering and Applications
基金 国家重点基础研究发展规划(973)(the National Grand Fundamental Research973Program of China under Grant No.2003CB716101)
关键词 低剂量X—CT Bayesian估计 Gibbs先验 广义Gibbs先验 low-dose X-CT Bayesian estimation Gibbs prior generalized Gibbs prior
  • 相关文献

参考文献16

  • 1Li T,Li X,Wang J,et al.Nonlinear sinogram smoothing for low- dose X-ray CT[J].IEEE Transactions on Nuclear Science,2004,51 (5) : 2505-2513.
  • 2La Riviere P J,Billmire D M.Reduction of noise-induced streak artifacts in X-ray computed tomography through Spline-based penalized-likelihood sinogram smoothing[J].IEEE Transactions on Medical Imaging, 2005,24( 1 ) : 105-111.
  • 3La Riviere P J.Penalized-likelihood sinogram smoothing for low dose CT[J].Medical Physics, 2005,32:1676-1683.
  • 4Wang J,Li T,Lu H,et al.Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography[J].IEEE Transactions on Medical Imaging, 2006,25 ( 10 ) : 1272-1283.
  • 5Wang J,Li T,Lu H,et al.Noise reduction for low-dose single-slice helical CT sinograms[J].IEEE Transactions on Nuclear Science, 20()6, 53(3 ): 1230-1237.
  • 6Hsieh J.Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise[J].Medical Physics, 1998,25:2139-2147.
  • 7KachelrieB M,Watzke O,Kalender W A.Generalized multi--dimensional adaptive filtering for conventional and spiral single-slice,multislice, and cone-beam CT[J].Medical Physics, 2001,28: 475-490.
  • 8Demirkaya K.Reduction of noise and image artifacts in computed tomography by nonlinear filtration of the projection images[C]//Proc SPIE Medical Imaging,2001,4322:917-923.
  • 9Bowsher J E,Johnson V E,Turkington T G,et al.Bayesian reconstruction and use of anatomical a priori information for emission tomography[J].IEEE Transactions on Medical Imaging, 1996,15(5). 673-686.
  • 10Daniel F Yu,Fessler A.Edge-preserving tomographic reconstruction with nonlocal regularization[J].IEEE Transactions on Medical Imaging, 2002,21 (2) : 159-173.

同被引文献39

引证文献9

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部