摘要 针对温湿度耦合控制空调系统存在能耗大、设备工作效率低等问题,提出了对空调系统采用温湿度非耦合控制的方法,以提高空调系统的效率,降低空调系统的能耗。 According to these existed problems of air conditioner system for non-coupling controlling in temperature and humidity with a high energy dissipation and low operating efficiency for equipment and so on.The paper puts forward that air conditioner system should be adopted the method of non-coupling with temperature and humidity,so as to accelerate the efficiency of air conditioner system and lower its energy dissipation.
作者 林爱晖
出处 《山西建筑》 2008年第16期172-173,共2页 Shanxi Architecture
关键词 非耦合控制 能耗 节能 空调系统 non-coupling controlling,energy dissipation,energy-saving,air conditioner system
  • 相关文献

参考文献5

二级参考文献12

  • 1江亿,薛志峰,曾剑龙,耿克成,姜子炎.清华大学超低能耗示范楼[J].暖通空调,2004,34(6):64-66. 被引量:20
  • 2陈晓阳,江亿,李震.湿度独立控制空调系统的工程实践[J].暖通空调,2004,34(11):103-109. 被引量:76
  • 3谢晓云,江亿,陈晓阳,曲凯阳.利用盐溶液制备冷水的冷水机组[J].暖通空调,2004,34(11):110-113. 被引量:4
  • 4张伟荣,曲凯阳,刘晓华,常晓敏.溶液除湿方式对室内空气品质影响的初步研究[J].暖通空调,2004,34(11):114-117. 被引量:24
  • 5汪维,王孝英,孙丽亨,等.上海生态建筑示范楼技术集成体系.见:2004年国际可持续发展建筑中国区会议论文集.2004
  • 6Li Z, Liu X, Jiang Y, et al. A new type of outdoor air processor with liquid desiccant total heat recovery. In: Proceedings of 4th International Symposium on HVAC, Tsinghua, Beijing, 2003
  • 7ASHRAE. ASHRAE Handbook Fundamentals, 2001
  • 8Busweiler U. Air-conditioning with a combination of radiant cooling, displacement ventilation and desiccant cooling. In: ASHRAE Trans. 1993, 99 (2). 503-509
  • 9Kosar D R, Witte M J, Shirey D B. Dehumidificationissues of Standard 62 - 1989. ASHRAE J, 1998, 40 (3):71-75
  • 10Niu J L. Developing a decoupled cooling and dehumidification air-conditioning system. In: Proceedings of 3rd International Symposium on HVAC, Shenzhen, 1999