摘要
介绍了 HFETR 十年运行中所积累的一部分实践经验,如最大允许功率的简化计算方法、控制棒间干涉效应及相对效率刻度、冷却系统改进后的特性及安全分析、运行中的失水监督等,最后,还对发生的事故及其处理方法作了简要介绍。
In this paper,some of practical experiences obtained from the dec-adal operation of HFETR are described,such as the simplified calcula-tion method of the maximum permissible power,interference effect andrelative efficiency calibration of control rods.Features of primary cool-ant system after improvement,loss of coolant monitoring during operationand so on.Also,accident analysis and treatment are briefly introduced.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1990年第6期11-20,共10页
Nuclear Power Engineering
关键词
运行
计算
HFETR
HFETR
Operation experience
Simplifed calculation method
Relative efficiency calibration
Operation safety