期刊文献+

热管空气预热器在420t/h锅炉上的应用研究 被引量:3

Study on the application of heat pipe air preheater in 420 t/h boilers
下载PDF
导出
摘要 针对菏泽发电厂2号锅炉低温段下级管式空气预热器腐蚀、堵灰以及漏风严重导致锅炉处于不经济和限出力运行的问题,对空气预热器的腐蚀和堵灰进行了分析。通过严格控制排烟温度,采用镍基渗层钎焊螺旋翅片管的热管空气预热器替换原低温段下级管式空气预热器,并进行了测试和观察。结果表明:低温段下级热管空气预热器运行情况良好、性能稳定,未发生堵灰、腐蚀、磨损、漏风现象,同时减少了送、引风机厂用电率,提高了锅炉效率。 In view of the problems in low-level heat pipe air preheat for No. 2 Boiler of Heze Power Plant, such as uneconomic operation and limited output, the corrosion and ash blockage in air preheater were analyzed. The temperature of exhaust gas was strictly.controlled and the original air heater was replaced by the brazing osmosis layer spiral finned tube economizer. The test results indicate that the retrofitted air preheater is in healthy and stable operation without any ash blockage, corrosion, erosion and air leakage problems. In addition, the self-service power consumption for FD and ID fans has been reduced and the boiler efficiency has been increased.
出处 《中国电力》 CSCD 北大核心 2008年第6期43-46,共4页 Electric Power
关键词 热管空气预热器 锅炉 低温腐蚀 堵灰 heat pipe air preheater boiler low-temperature corrosion ash blockage
  • 相关文献

参考文献6

二级参考文献8

  • 1钱伯章.热管换热器的发展和应用[J].化工机械,1996,23(5):47-54. 被引量:8
  • 2孙家庆 徐开义 沈诠 阮中坚 邓钊华 石奇光.膜式对流管束排列方式不同与不同管径对灰磨损影响的实验研究[A]..九十年代动力工程科技与动力设备的展望,中国动力工程学会第主届学术年会论文集[C].,1992.7.
  • 3胡荫平 辛国华 胡光.横向外螺旋肋片管省煤器在我国电站锅炉中应用前景的探讨[A]..九十年代动力工程科技与动力设备的展望,中国动力工程学会第六届学术年会论文集[C].,1992.7.
  • 4吴永生 方可人编.热工测量及仪表[M].水利电力出版社,1997..
  • 5[4]商政宋.实用热管技术.北京:化学工业出版社,1998
  • 6陈学俊 陈听宽主编.锅炉原理[M].机械工业出版社,1991..
  • 7李永华.等.电站锅炉空气预热器[M].北京:中国电力出版社.2002.
  • 8钱新任.谏壁发电厂8号炉螺旋鳍片省煤器改造[J].中国电力,1998,31(1):18-19. 被引量:1