摘要 针对在测定真密度的过程中,存在测量结果再现性不良等不足,提出了简便可行的粉体真实体积测定及真密度的计算方法。通过对粉末状粘土和硅藻土物料的标准液和真空度的合理选择、实际测定、计算及分析,得到了再现性良好、准确可靠真密度值等结论。 There is much deficiency while measuring the real densities of materials, such as the poor recurrence. This paper presented a convenient and feas/ble method for measuring really volume of power and calculating the real density. The real density obtained in the paper not only recur well but also nicety and cred/bility by selecting appropriate normal fluid and vacuum degree.
出处 《过滤与分离》 CAS 2008年第2期24-26,共3页 Journal of Filtration & Separation
关键词 真密度 双比重瓶 再现性 real density double specific gravity bottles repeatability
  • 相关文献

参考文献6

二级参考文献15

共引文献13

同被引文献33

  • 1刘昊,何涌.双比重瓶粉体真密度测定法[J].计量与测试技术,2005,32(3):39-40. 被引量:4
  • 2梁迪超.进口铁矿的技术经济评估[J].鞍钢技术,1996(4):1-9. 被引量:3
  • 3刘昊,何涌.矿物材料真密度测定方法的改进[J].矿物学报,2005,25(4):321-324. 被引量:9
  • 4李晖,张嫦,陈峰,王晓东.高纯硅微粉真密度的测定[J].西南民族大学学报(自然科学版),2007,33(2):344-346. 被引量:4
  • 5国家质量监督检验检疫总局.旋转黏度计检定规程(JJG1002-2005).北京:中国计量出版社,2005.
  • 6国家质量技术监督局.测量不确定度评定与表示(JJF1059-1999).北京:中国计量出版社,1999
  • 7Iveson S M, Holt S, Biggs S. Advancing Contact Angle of Iron Ores as a Function of Their Hematite and Goethite Content: Implications for Pelletising and Sintering[J].International Journal of Mineral Processing,2004,74 (1- 4):81.
  • 8Maeda Takayuki, Chieko Fukumoto, Toshihide Matsumura, et al. Effect of Adding Moisture and Wettability on Granula- tion of Iron Ore [J]. Tetsu to Hagane, 2006,92 (12) : 721.
  • 9LOXW, BAICQ, ZHOU H, et al. New Method to Deter- mine Optimum Water Content for Iron Ore Granulation [J]. Ironmaking and Steelmaking, 2010,37 (6) : 407.
  • 10Iveson S M, Holt S, Biggs S. Contact Angle Measurements of Iron Ore Powders[J].Colloids and Surfaces A: Physicochemi- cal and Engineering Aspects, 2000,166 (1-3): 203.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部