期刊文献+

一种新型离子交换树脂在扩张床中性能的研究 被引量:1

The Properties of a New Ion-exchange Resin in Expanded Bed
下载PDF
导出
摘要 在扩张床中研究了以水或甘油水溶液为流动介质,新型离子交换树脂CG-6在不同流速、粘度和床层沉降高度条件下的扩张率及柱效能,并使用牛血清白蛋白进行了扩张床吸附穿透实验。结果表明CG-6树脂在扩张床条件下具有很好的柱效能,轴向混合系数可达到10-6数量级,并且树脂对牛血清白蛋白有很高的吸附量,并且在合适的条件下有较好穿透性能。说明CG-6树脂适合于蛋白质的扩张床吸附,所得结果将在CG-6树脂在蛋白质分离纯化的应用中提供重要的参考依据。 A new ion-exchange resin , CG-6 is Experimented in a expanded bed. The ratio of expanding and column efficiency is determined at different flow velocity, viscosity and sediment bed height using water or glycerol solution as the fluid medium. The break through curves of Bovine Serum Albumin in expanded bed are also described. CG-6 shows very great column efficiency, the magnitude of axial mixing coefficient can reach 10-6. CG-6 has very great adsorption capability and rather fine break through property in appropriate conditions. The results demonstrate that CG-6 is suitable for the adsorption of protein in expended bed. This article will provide important basis for the application of CG-6 in purification of protein.
出处 《过滤与分离》 CAS 2008年第2期27-29,33,共4页 Journal of Filtration & Separation
关键词 扩张床 吸附 离子交换树脂 expanded bed adsorption ion-exchange resin.
  • 相关文献

参考文献6

二级参考文献19

  • 1商振华,于亿年.亲和膜分离技术(I)—原理和材料[J].膜科学与技术,1995,12(2):1-11. 被引量:5
  • 2商振华,于亿年.亲和膜分离技术(Ⅱ)—方法和应用[J].膜科学与技术,1995,15(4):1-6. 被引量:5
  • 3商振华 于亿年.-[J].膜科学与技术,1995,15(2):1-1.
  • 4-.上海第四制药厂原总工程师孙善丹访谈[M].,1998..
  • 5蔡顺养 孙德芳 等.抗菌素研究(II)抗菌素的生产工艺[M].上海:上海科学技术出版社,1963.343-353.
  • 6胡洪波.扩张床吸附过程的研究-安通溶栓梅的分离与纯化:博士学位论文[M].杭州:浙江大学,1999..
  • 7Chang Y K,Biotechnology Bioengineering,1996年,49卷,204页
  • 8Chang Y K,Biotechnology Bioengineering,1995年,48卷,355页
  • 9Huang P Y,Biotechnology Bioengineering,1995年,47卷,288页
  • 10上海第四制药厂原总工程师孙善丹访谈,1998年

共引文献30

同被引文献14

  • 1陈刚,赵红卫,徐琦,邱家山,方为茂,钟本和,张乃科,何琦.离子交换树脂吸附分离人凝血酶原复合物研究[J].四川化工,2006,9(5):4-8. 被引量:3
  • 2Chase HA, Draeger NM. Expanded-bed adsorption of proteins using ion-exchangers[J]. Sep Sci Technol, 1992,27 (14) : 2021-2039.
  • 3Chase HA. Purification of proteins by adsorption chromatography in expanded beds [J]. Trends Biotechnol, 1994, 12 (8):296-303.
  • 4Th6mmes J, Bader A, Halfar M, et al. Isolation of monoclonal antibodies from cell containing hybridoma broth using a protein A coated adsorbent in expanded beds[J]. J ChromatogrA, 1996, 752 (1-2) : 111-122.
  • 5雷引林,金志华,姚善泾,等.一种扩张床装置:中国,1583211[P].2005-02-23.
  • 6Chang YK, Chase HA. Development of operating conditions for protein purification using expanded bed techniques: the effect of the degree of bed expansion on adsorption performance [J]. Biotechnol Bioeng, 1995, 49 (5) : 512-526.
  • 7Bruce LJ, Ghose S, Chase HA. The effect of column verticality on separation efficiency in expanded bed adsorption [J]. Bioseparation, 1999, 8 (1-5): 69-75.
  • 8Asghari F, Jahanshahi M. Fabrication and evaluation of low- cost agarose-zinc nanoporous composite matrix: influence of adsorbent density and size distribution on the performance of expanded beds [J]. JChromatogrA, 2012, 1257: 89-97.
  • 9McCann KB, Gomme PT, Wu J, et al. Evaluation of expanded bed adsorption chromatography for extraction of prothrombin complex from Cohn Supernatant I [J]. Biologicals, 2008, 36 (4) : 227-233.
  • 10Lihme A, Hansen MB, Andersen IV, et al. A novel core fractionation process of human plasma by expanded bed adsorption chromatography [J]. Anal Biochem, 2010, 399(1): 102-109.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部