摘要
对3块新浇筑的素混凝土板和10根旧钢筋混凝土梁采用超声回弹综合法和钻芯法进行混凝土强度检测。研究了超声回弹综合法和钻芯法所测混凝土抗压强度值与标准立方体抗压强度三者的相互关系,并着重研究了100,75和50三种不同直径芯样所测混凝土抗压强度值的相互关系。在综合分析相关研究成果的基础上,得到小直径芯样所测混凝土抗压强度相对标准直径的芯样所测混凝土抗压强度的修正系数。可为混凝土强度现场检测提供参考。
The concrete strength of three new concrete slabs and ten old reinforced concrete beams are tested by the means of ultrasonic-resilience testing method and core-drilling testing method. And based on the test results, the relations of the concrete strength respectively tested by the ultrasonic-resilience testing method, core-drilling testing method and the cube strength testing method are studied. The differences and relations of the concrete strength tested by core-drilling testing method with core specimens of different diameter such as 100mm, 75mm and 50mm are focused. Along with the former research results, the correction coefficient of the concrete strength obtained by core specimens of small diameter are studied and established. All these will be helpful to concrete strength testing engineering and former studying on the testing techniques.
出处
《建筑结构》
CSCD
北大核心
2008年第5期80-82,共3页
Building Structure
基金
福建省自然科学基金(E0540006)
华侨大学校科研计划(531167)
福建省青年科技人才创新基金(2005J32)
关键词
混凝土强度检测
超声回弹综合法
钻芯法
小直径芯样
修正系数
concrete strength testing
ultrasonic-resilience testing method
core-drilling method
core specimen of small size
correction coefficient