摘要
利用非对称Sagnac干涉仪得到光孤子振幅压缩态,并利用平衡零差探测系统对其进行测量。本文重点讨论了测量孤子压缩态的光电探测器,给出了设计方案以及测试指标。其中3dB带宽约为10MHz,饱和功率约为19mW。利用该探测器测得孤子压缩值约为1.1dB,考虑系统整体探测效率(75%),可达约1.5dB。
Soliton amplitude squeezing state is obtained by using an asymmetric Sagnac interferometer,and detected by using a balanced homodyne detecting system. A promoted photo detector drcuit is introduced which is fit for quantum state detecting. The circuit using ETX-500 photodiode has a bandwidth of 10 MHz and the saturation power is about 19mW. A maxi mum photocurrent noise reduction of 1.1 dB bdow shot noise is achieved. Taking the detecting efficiency into account, the squeezing will be about 1.5 dB.
出处
《光电子.激光》
EI
CAS
CSCD
北大核心
2008年第6期832-834,共3页
Journal of Optoelectronics·Laser
基金
国家自然科学基金资助项目(60378011
60578043)
北京市教育委员会共建项目建设计划资助项目(XK100130537)
关键词
量子通信
压缩态
孤子
探测器
非对称Sagnac干涉仪
quantum communication
squeezing state
soliton
detector
asymmetric Sagnac interferometer