期刊文献+

基于能量守恒的无创血糖检测传感器的设计 被引量:9

Design of Non-Invasive Blood Sugar Measuring Sensor Based on Energy Metabolic Conversation
下载PDF
导出
摘要 根据人体摄取的能量和代谢消耗的能量守恒原理,建立了对流、蒸发、辐射等与血糖浓度之间的关系,提出了一种基于能量守恒的无创血糖检测传感器的设计。设计中将湿度、温度、血氧饱和度、热辐射等传感器集成封装成一个内径Φ为15mm×50 mm无创血糖检测传感器。该传感器性能稳定,测得的数据经多项式拟合后较为理想。 A new method is presented to design a transducer for measuring blood sugar level non-invasively, which is based on the energy metabolic conservation law. According to the energy metabolic conservation law that the energy derived by human body equals consumed energy by metabolism, this method establishes the relationship between convection, evaporation, radiation and the blood sugar level. The transducers measuring humidity, temperature, degree of blood oxygen saturation and heat radiation respectively, are integrated as one with the inner diameter of 15 minx 50 mm in this design, which is used to measure the blood sugar level non-invasively. This transducer has the advantages of stable, and it has good fit result for testing data.
出处 《传感技术学报》 CAS CSCD 北大核心 2008年第5期724-728,共5页 Chinese Journal of Sensors and Actuators
基金 中南大学博士后科学基金资助(20060120) 湖南省自然科学基金资助(07JJ6133)
关键词 能量代谢守恒 血糖检测 传感器 energy metabolic conservation blood glucose measurement sensor
  • 相关文献

参考文献14

  • 1Katsuhiko Maruo, Mitsuhiro Tsurugi, Jakusei Chin, et al. Noninvasive Blood Glucose Assay Using a Newly Developed Near-Infrared System[J]. IEEE Journal of Selected Topics in Quantum Electronics,2003,9(2):322-330.
  • 2Xu Kexin, Qiu Qingjun, Jiang Jingying, et al. Non-Invasive Glucose Sensing with Near-Infrared Spectroscopy Enhanced by Optical Measurement Conditions Reproduction Technique[J]. Optics and Lasers in Engineering, 2005,43 : 1096-1106.
  • 3Naroo Kang, Sumaporn Kasemsumran, Young-Ah Woo, et al. Optimization of Informative Spectral Regions for the Quantification of Cholesterol, Glucose and Urea in Control Serum Solutions Using Searching Combination Moving Window Partial Least Squares Regression Method with Near Infrared Spectroscopy[J]. Chemometrics and Intelligent Laboratory Systems, 2006,82 :90-96.
  • 4Berger Andrew J, Irving Itzkan and Feld Michael S. Feasibility of Measuring Blood Glucose Concentration by Near-Infrared Raman Spectroscopy[J]. Molecular and Biomolecular Spec troscopy. 1997,53(2) :287-292.
  • 5Williams K, Wertheim D. Computer Analysis of Photo-Acoustic Signals to Aid Development of a Non Invasive Blood Glucose Sensor[C]// Eurocon 2003. Computer as a Tool. The IEEE Region 2003, 2: 202-203.
  • 6Nikawa Y, Someya D. Non-Invasive Measurement of Blood Sugar Level by Millimeter Waves[C]// Microwave Symposium Digest 2001 IEEE MTT-S International. 2001, 1: 171- 174.
  • 7Clovis D. Eyeglass Glucometer[C]// Bioengineering Conference, 2003 IEEE 29th Annual, Proceedings. 2003: 246-247.
  • 8Tamada Janet A, Satish Garg, et al. Noninvasive Glucose Monitoring Comprehensive Clinical Results [J]. JAMA, 1999, 282, 1839-1844.
  • 9Masaki Yamaguchi, Masayuki Mitsumori, Yoshio Kano. Development of Noninvasive Procedure for Monitoring Blood Glucose Levels Using Saliva[C]// Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1998,20 (4):1763-1766.
  • 10Ok Kyung Cho, Yoon Ok Kim, Hiroshi Mitsumaki, Katsuhiko Kuwa. Noninvasive Measurement of Glucose by Metabolic Heat Conformation Method[J]. Clinical Chemistry, 2004, 50 (10) : 1-6.

二级参考文献3

共引文献28

同被引文献85

引证文献9

二级引证文献33

相关作者