期刊文献+

高速电阻层析成像数据采集系统设计 被引量:7

High-Speed Data Acquisition System of Electrical Resistance Tomography
下载PDF
导出
摘要 针对目前电阻层析成像(ERT)系统实时性欠佳的问题,研制成功一套基于DSP和USB2.0技术的ERT数据采集系统。模块化设计保证了系统良好的可维护性和可扩展性,双极性脉冲电流激励技术和优化的结构设计实现了系统高速的数据采集能力,从而突破了ERT系统数据采集速度的瓶颈问题。测试结果表明,系统在取得良好精度的同时达到1464帧/秒的数据采集速度,满足了实际工业应用的实时性要求。 To improve real-time character of electrical resistance tomography (ERT) system, a data acquisi- tion system for ERT based on DSP and USB2. 0 was developed. The system was designed in a modular fashion , which was easy to maintain and convenient to expand. High - speed data capture rate could be achieved due to utilizing a switched dc current pulse technique and optimized system structure, which solved the bottleneck of data acquisition speed of ERT system. Test results show that a data capture rate of more than 1400 frame/s can be achieved with a satisfying precision, which meets the real-time requirement of process industry.
出处 《传感技术学报》 CAS CSCD 北大核心 2008年第1期79-82,共4页 Chinese Journal of Sensors and Actuators
基金 国家自然科学基金资助(60532020 50576084)
关键词 电阻层析成像 DSP USB2.0 双极性电流脉冲 高速 electrical resistance tomography (ERT) DSP USB2.0 switched dc current pulse high-speed
  • 相关文献

参考文献5

  • 1KOTRE C J.A Sensitivity Coefficient Method for the Reconstruction of Electrical Impedance Tomograms[J].Clinical Physics and Physiological Measurement,1989,10(3):275 -281.
  • 2Cilliers J J,Xie W,Neethling S J,Randall E W,Wilkinson A J.Electrical Resistance Tomography Using a Bi-Directional Current Pulse Technique[J].Measurement Science & Technology,2001,12(8):997-1001.
  • 3EZ-USB FX2 Technical Reference Manual v2.1[EB/OL].http://www.cypress.com,2001.
  • 4王化祥,曹章.电阻抗层析成像系统“软场”非线性特性——基于统计的方法[J].天津大学学报,2006,39(5):543-547. 被引量:4
  • 5Wang M.Inverse Solutions for Electrical Impedance Tomography Based on Conjugate Gradients Methods[J].Measurement Science & Technology,2002,13(1),101-11.

二级参考文献11

  • 1Geselowitz D B. An application of electrocardiographic lead theory to impedance plethysmography [ J ]. IEEE Trans Blot, ted Eng,1971, 18(1) :38-41.
  • 2Lehr J. A vector derivation useful in impedance plethysmographic field calculations [ J ]. IEEE Trans Biomed Eng,1972,19 (2) : 156-157.
  • 3Murai T, Kagawa Y. Electrical impedance computed tomography based on a finite element model[ J ]. IEEE Trans Biomed Eng,1985 ,32( 3 ) :177-184.
  • 4Williams R A, Beck M S. Process Tomography-Principles,Techniques and Applications [ M ]. Woburn, MA: Butterworth-Heinemanns, 1995.
  • 5Kotre C J. EIT image reconstruction using sensitivity weighted filtered back-projection [ J ]. Phsiol Meas, 1994, 15(Suppl 2A) : 125-136.
  • 6Cheney M, Isaacson D, Newell J, et al. NOSER: An algorithm for solving the inverse conductivity problem[ J]. Int J Imaging Syst Technol ,1990 , 2:66-75.
  • 7Wang Min. inverse solutions for electrical impedance tomography based on conjugate gradients methods [ J ]. Meas Sci Technol, 2002,13 ( 1 ) : 101-117.
  • 8Aster R, Borchers B, Thurber C. Parameter Estimation and Inverse Problems [ M ]. San Diego, USA : Academic Press,2004.
  • 9Lukaschewitsch M, Maass P, Pidcock M. Tikhonov regularization for electrical impedance tomography on unboundeddomains [ J ]. Inverse Problems ,2003,19 ( 3 ) :585-610.
  • 10Barrett R, Berry M, Chan T F, et al. Templates for the Solution of Linear Systems: Building Blocks for Iterative Methods [ M ]. 2nd ed. Philadelphia: SIAM, 1994.

共引文献3

同被引文献72

引证文献7

二级引证文献36