摘要 目的比较研究Free-edge托槽和传统托槽的摩擦力特点,为临床应用提供理论依据。方法在干燥条件下,测试2种Free-edge托槽、2种传统托槽和4种弓丝分别组合的动、静摩擦力。结果Free-edge托槽中间翼结扎摩擦力极小;六翼结扎摩擦力最大。结论Free-edge托槽可解决低摩擦力与高牙齿控制能力的矛盾,改进方丝弓系列固定矫正器的性能,其应用有利于提高临床矫正疗效。 Objective To testing frictional force of free-edge bracket and conventional bracket and the rationale and clinical application of free-edge bracket. Method In the dry states, the static and kinetic frictional force of different combinations of 2 kinds of free-edge brackets and 2 kinds of conventional brackets coupled with 4 kinds of archwires were tested. Result When Free-edge bracket's middle wings were ligated, the frictional force was decreased to zero; when Free-edge bracket' six wings were ligated, the frictional force was greatest. Free-edge bracket solved the contradiction between less frictional force and better tooth control, the bracket improved the capability of the series of edgewise fixed appliance. Conclusion The free-edge bracket solved the contradiction between less frictional force and improved the capability of edgewised fixed application, increase the effectiveness of orthodontic treatment.
出处 《福建医科大学学报》 2008年第3期243-247,共5页 Journal of Fujian Medical University
基金 福建省教育厅科研基金资助项目(JA01068)
关键词 正畸托架 摩擦 正畸金属丝 orthodontic brackets frictrion orthodontic wires
  • 相关文献

参考文献17

  • 1Thorstenson G A, Kusy R P. Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states[J]. Angle Orthod, 2003,73 (4) :418-430.
  • 2Voudouris J C. Interactive edgewise mechanisms: form and function comparison with conventional edgewise brackets[J]. Am J Orthod Dentofacial Orthop, 1997,111(2):119-140.
  • 3Thorstenson G A, Kusy R P. Comparison of resistance to sliding between different self-ligating brackets with second-order angulation in the dry and saliva states[J]. Am J Orthod Dento facial Orthop, 2002,121(5) :472-482.
  • 4Cacciafesta V, Sfondrini M F, Ricciardi A, et al. Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations[J]. Am J Orthod Dentofacial Orthop, 2003, 124 (4): 395-402.
  • 5Damon D H. The rationale evolution and clinical application of the self-ligating bracket[J]. Clin Orthod Res, 1998,1(1) :52- 61.
  • 6Harradine N W, Birnie D J. The clinical use of Activa self-ligating bracket[J]. Am J Orthod Dentofacial Orthop, 1996, 109(3) :319-328.
  • 7实用新型专利.设计人:梁甲兴.专利名称:牙齿矫正用托槽.专利号:03269078.9.申请日:2003.07.18.公开号:CN2643853,公开日:2004.09.29.
  • 8林和平 ,吴建勇 .不同直丝托槽与弓丝在后牙段摩擦力的实验研究[J].口腔正畸学,2005,12(2):60-63. 被引量:6
  • 9张玉华,梁甲兴,林立.结扎方式与结扎力对托槽-弓丝-结扎丝结构摩擦力的影响[J].福建医药杂志,2002,24(4):29-30. 被引量:12
  • 10梁甲兴,张玉华,闵宝乾,林立.托槽弓丝组合对托槽-弓丝-结扎丝结构摩擦力的影响[J].福建医科大学学报,2002,36(3):260-262. 被引量:6

二级参考文献51

  • 1曾祥龙.自锁托槽直丝弓矫治器的初步应用[J].中华口腔正畸学杂志,1996,12(1):25-27. 被引量:6
  • 2缪耀强,刘从华,李兰超.SPEED矫治器在临床的初步应用[J].口腔正畸学,2004,11(3):99-102. 被引量:6
  • 3Zufall SW,Kusy RP. Sliding mechanics of coated composite wires and the development of an engineering model for binding[J]. Angle orthod, 2000,70(1):34~47.
  • 4Gil FJ,Solano E,Campos A. Improvement of the friction behaviour of NiTi orthodontic archqires by nitrogen diffusion[J]. Biomed Mater Eng, 1998,8(5,6):335~342.
  • 5Kapila S,Angolkar PV,Duncanson MG. Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys[J]. Am J Orthod Dentofacial Orthop, 1990,98(3):117~126.
  • 6Schumacher HA,Bourauel C,Drecher D. The influence of bracket design on frictional losses in the bracket/arch wire system[J]. J Orofac Orthop, 1999,60(5):335~347.
  • 7Kusy BR,Whitley.BS. Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states[J]. Angle Orthod, 1991,61(4):293~302.
  • 8Drescher D,Bourauel D,Schumacher HA. Frictional forces between bracker and arch wire[J]. Am J Orthod Dentofac Orthop, 1989,96(5):397~404.
  • 9Bednar JR,Gruendeman GW,Sandrik JL. A comparative study of frictional forces between orthodontic brackets and arch wires[J]. Am J Orthod Dentofacial Orthop, 1991,100(6):513~522.
  • 10Garner LD,Allai WW,Moore BK. A comparison of frictional forces during simulated canine retraction of a continuous edgewise archwire[J]. Am J Orthod Dentofac Orthop, 1986,90(3):199~203.

共引文献56

同被引文献60

引证文献7

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部