摘要 针对支架制造热点问题,提出了加工冠状动脉支架管材的采购要求;结合生产经验,强调了加工过程检验作为判定管材选取所具有的决定性作用。通过对比来料检验和加工检验结果,认为加工过程检验是冠状动脉支架管材选取和确认必不可少的一环,可作为优选管材的依据。 Based on concerns during stents manufacturing, the tubing purchase specifications of coronary stents have been proposed, and the key role of process inspection for judging the qualified tubing have been justified. By comparing the incoming inspection and the process inspection, it is concluded that the process inspection, as basis for optimizing tubing, is indispensable for selecting and confirming the tubing.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2008年第19期3796-3798,共3页 Journal of Clinical Rehabilitative Tissue Engineering Research
基金 江苏省高技术研究重大项目(BG2006012)~~
  • 相关文献

参考文献1

二级参考文献13

  • 1I. Kaare Tesdal,Werner Jaschke,Mathias Bühler,Ralf Adamus,Thomas Filser,Eggert Holm,Max Georgi.Transjugular intrahepatic portosystemic shunting (TIPS) with balloon-expandable and self-expanding stents: Technical and clinical aspects after 3 1/2 years’ experience[J].Cardiovascular and Interventional Radiology.1997(1)
  • 2Ugo Ugolotti,Pietro Larini,Carla Marcato,Andrea Saccani,Franca Puccianti,Giovanni Pedretti.Is the tantalum Strecker stent suitable for TIPS creation? short- and mid-term results in 20 consecutive patients[J].Cardiovascular and Interventional Radiology.1997(1)
  • 3G. Noeldge,G. M. Richter,M. Roessle,K. Haag,B. T. Katzen,G. J. Becker,J. C. Palmaz.Morphologic and clinical results of the transjugular intrahepatic portosystemic stent-shunt (TIPSS)[J].Cardiovascular and Interventional Radiology.1992(5)
  • 4Hausegger KA,Lamrner J,Fluckiger F,Lafer M,Klein GF,Pilger E.Iliac artery stenting-clinical experience with the Palmaz stent, Wallstent, and Strecker stent[].Acta Radiologica Diagnosis.1992
  • 5Rosch J,Uchida BT,Putnam JS,Buschman RW,Law RD,Hershey AI.Experimental intrahepatic portacaval anastomosis: use of expandable Gianturco stents[].Radiology.1987
  • 6Ikari Y,Hara K,Tamura T,Saeki F,Yamaguchi T.Luminal loss and site of restenosis after Palmaz-Schatz coronary stent implantation[].The American Journal of Cardiology.1995
  • 7Lossef SV,Lutz RJ,Mundorf J,Barth KH.Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis[].Journal of Vascular and Interventional Radiology.1994
  • 8Palmaz JC.Intravascular stents: tissue-stent interactions and design considerations[].American Journal of Roentgenology.1993
  • 9Matsuzaka S,Kanazawa H,Kobyashi M,Kumazaki T.An experience of transjugular intrahepatic portosystemic shunt in the treatment of gastroesophageal varices[].Nippon Shokakibyo Gakkai Zasshi.1994
  • 10Tominaga R,Kambic HE,Emoto H,Harasaki H,Hollmen J.Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits[].American Heart Journal.1992