期刊文献+

相机真空热试验的红外笼模拟方法研究 被引量:3

A New Type IR Array Used in Space Camera Thermal Test
下载PDF
导出
摘要 空间相机的热平衡/热真空试验中,一般采用红外笼-热流计的闭环控制系统来模拟相机进光口处的外热流。由于对相机光路的遮挡,通用的平板式红外笼难以满足热真空试验中相机的成像要求。文章在分析的基础上设计了一种圆筒式红外笼,同时满足了热平衡试验的外热流模拟要求和热真空试验相机的成像要求;对同一台相机采用两种红外笼的试验结果进行了对比分析。 In the thermal balance/vacuum test (TBT/TVT) of a space camera, an IR array-radiometer closed system is usually used near the camera's window to simulate the arriving heat flux. The most commonly used flat IR array can not satisfy the requirements because of its block to the light ray. A column IR array has been designed, which can satisfy both the heat flux (in TBT) and imaging (in TVT) requirements. Test results for two different types of IR array were compared and analyzed.
出处 《航天器工程》 2008年第3期62-66,共5页 Spacecraft Engineering
关键词 空间相机 热试验 红外笼 space camera thermal test IR array
  • 相关文献

参考文献1

共引文献1

同被引文献25

  • 1范含林,文耀普.航天器热平衡试验技术评述[J].航天器环境工程,2007,24(2):63-68. 被引量:33
  • 2游思梁,王淦泉,陈桂林.基于Matlab的FY-4星载扫描辐射计午夜太阳入侵模拟[J].上海航天,2006,23(5):46-49. 被引量:8
  • 3国防科学技术工业委员会.航天器热平衡试验方法[S],20063-10.
  • 4杨晓宁.空间外热流红外模拟理论与技术研究[D]北京:中国空间技术研究院,2008.
  • 5Asteggiano C,Guglielmo C,Sacchi E. The I/R thermal balance test of Radarsat-2:Approach to verification/correlation[A].Rome,Italy,2005.
  • 6国防科学技术工业委员会.航天器热平衡试验方法[S]北京:国防科学技术工业委员会,20063-10.
  • 7闵桂荣;郭舜.航天器热控制[M]北京:科学出版社,1998.
  • 8闵桂荣;张正纲.卫星热控制技术[M]北京:宇航出版社,1991.
  • 9侯增祺;胡金刚.航天器热控制技术--原理及其应用[M]北京:中国科学技术出版社,2007.
  • 10何知朱.新型热控材料器件及应用[M]北京:宇航出版社,1988.

引证文献3