期刊文献+

反相毛细管电色谱中两种电渗流测定方法的比较 被引量:3

Comparison of Electroosmotic Flow Measuring by Two Methods in Reversed Capillary Electrochromatography
下载PDF
导出
摘要 在毛细管电色谱中电渗流的测定方法有许多种,常用的是示踪剂法。本文将硫脲示踪剂法和迭代分析法测定的电渗流结果加以对比分析,结果表明:在不同有机调节剂体积分数、不同电压、不同电解质浓度下,虽然用两种方法测得的电渗流随诸因素的变化规律符合电渗流变化的一般规律,但强极性硫脲分子存在电迁移现象,使测得的电渗流较真实值有所偏离。偏离的大小随有机调节剂体积分数、电解质浓度等实验条件变化。 There are many methods in measuring electroosmotic flow. The common one is to use a marker. In this article, the dead time was obtained by two methods. One was by using thiourea as a marker, from linear and the other was regression of benzene homologue. Based on the dead time obtained from these two methods, characteristics of electroosmatic flow in reversed phase capillary electrochromatogrphy were investigated under the conditions of different organic modifier, separating voltage and ionic strength. The results showed that they obeyed the common law, but the thiourea marker had the characteristics of migration and the electroosmatic flow measuring by this method has some weak change due to the different conditions.
出处 《分析科学学报》 CAS CSCD 2008年第3期249-253,共5页 Journal of Analytical Science
基金 国家自然科学基金(No.20605023) 辽宁省博士后基金(No.2006921042)
关键词 毛细管电色谱 电渗流 硫脲 Capillary electrochromatography Electroosmatic flow Thiourea
  • 相关文献

参考文献22

  • 1Stahlberg J. J. Chromatogr. A[J], 2000,887: 187.
  • 2Rathore A S. Horvath C. J. Chromatogr. A[J],1996,743(2) :231.
  • 3Rathore A S. Electrophoresis[J], 2002,23(22-23) :3827.
  • 4Rathore A S, Horvath C. Anal. Chem.[J], 1998,70(15) : 3271.
  • 5Rathore A S, Horvath C. J. Chromatogr. A[J], 1997,781 : 185.
  • 6Tsuda T. Anal. Chem. [J], 1987,59(3) :521.
  • 7Wan Q. Anal. Chem. [J],1997,69(3):361.
  • 8Wan Q. J. Chromatogr. A[J], 1997,782 : 181.
  • 9Orlando L, Sanchez M, Ever P H, Michael L, Wolfgang L, Ernst K. Electrophoresis[J], 2003,24 (3) : 390.
  • 10Poppe H. Anal. Chem.[J] ,1992,64(17) :1908.

二级参考文献12

  • 1[1]Jan Stahlberg, J Chromatogr, 2000;A 887:187
  • 2[2]Rathore A S, Horvath Cs.J Chromatogr, 1997;A 781:185
  • 3[3]Rathore A S,Horvath Cs.J Chromatogr, 1996;A 743:231
  • 4[4]Rathore A S,Horvath Cs. Anal Chem, 1998;70:3069
  • 5[5]Rathore A S,Horvath Cs. Anal Chem, 1998;70:3271
  • 6[7]Wan Q. J Phys Chem, 1997;101:4860
  • 7[8]Wan Q. J Phys Chem, 1997;101:8449
  • 8[9]Wan Q. J Chromatogr, 1997;A 782:181
  • 9Lin J M,Fresenius J Anal Chem,1997年,357卷,130页
  • 10Yan C,Anal Chem,1995年,67卷,2026页

共引文献6

同被引文献47

  • 1尤慧艳,张维冰,张丽华,张玉奎.反相毛细管电色谱中无盐体系的优势及分离研究[J].分析科学学报,2004,20(6):580-582. 被引量:1
  • 2谭峰,杨丙成,关亚风.小型低压电渗输液泵的研究[J].分析化学,2006,34(2):280-282. 被引量:4
  • 3尤慧艳,郭明,张丽华,张维冰,张玉奎.两种填充型双电渗泵的制作与流量控制[J].色谱,2007,25(3):435-436. 被引量:4
  • 4吕海霞,王家斌,王晓春.整体柱毛细管电色谱法测定蔬菜中有机磷农药的含量[J].光谱实验室,2007,24(4):735-738. 被引量:7
  • 5VAN DEEMTER J J,ZUIDERWEG F J,KLINKENBERG A.Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography[J].Chem Eng Sci,1956,5(6):271-289.
  • 6SWARTZ M E.UPLCTM:An introduction and review[J].J Liq Chromatogr Relat Technol,2005,28(7):1253-1263.
  • 7HORVATH C,LIN H J.Movement and band spreading of unsorbed solutes in liquid chromatography[J].J Chromatogr:A,1976,126(3):401-420.
  • 8ANDRADE J S,ALMEIDA M P,MENDES J,HAVLIN S,SUKI B,STANLEY H E.Fluid flow through porous media:the role of stagnant zones[J].Phys Rev Lett,1997,79(20):3901-3904.
  • 9BABENKO Y I,GOLUBEVO V S.Compressible-liquid motion in porous medium with flowing and stagnant regions[J].J Eng Phys,1980,38(1):99-102.
  • 10LEINWEBER F C,TALLAREK U.Concentration polarization-based nonlinear electrokinetics in porous media:induced-charge electroosmosis[J].J Phys Chem:B,2005,109(46):21481-21485.

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部