通过对某电厂异步电动机连续6 a的电机事故情况的分析,总结出引起高压电动机和低压电动机烧损的各种事故原因,从理论上对主要原因进行分析,并提出相应的防范措施。
Analyzes the failures of asynchronous electromotor in successive 6 years, summarizes reasons for the short circuit of high voltage motor and low voltage motor. The main reasons are analyzed from theoretical aspect, and preventive measures were proposed accordingly.