期刊文献+

百太瓦飞秒激光驱动复合靶产生质子的特性研究 被引量:3

Proton Characteristic Research Generated by Hundred TW Femtosecond Laser and Compound Target Interaction
下载PDF
导出
摘要 在SILEX-I激光装置上实验研究了超强超短激光与Au/CH复合靶相互作用中在靶背法线方向发射的质子束的空间分布特征。保持复合靶前表面的Au厚度不变,质子束流随着后表面的C8H8层厚度的增加而减小,同时质子空间分布呈现环状、成丝和圆盘状分布。实验没有发现高于2.75MeV的高能质子产生。实验进一步完善了超短超强激光等离子体相互作用的物理模型。 Proton beam behavior at the normal direction of the rear surface of the target produced from ultra-intense short pulse laser irradiated Au/CH double layers targets was explored on SILEX-I laser facility. With the same thickness of Au layer, the proton beam flux decreases with the increasing of CH layer thickness, and the corresponding spatial profile of proton beam shows ring-, filament-, and disc-like distribution. The energy of proton beam was not beyond 2.75 MeV in our experiment.
出处 《原子核物理评论》 CAS CSCD 北大核心 2008年第2期135-138,共4页 Nuclear Physics Review
基金 四川理工学院人才引进项目(07ZR45)~~
关键词 超短超强激光 质子 质子空间分布 质子产额 辐射变色膜片 ultra-short and ultra-intense laser proton space attribution of proton yield of proton radiochromic film
  • 相关文献

参考文献13

  • 1Pukhov A. Phys Rev Lett, 2001, 86:3 562.
  • 2Borghesi M, Schiavi A, Campbell D H, et al. Plasma Physics and Controlled Fusion, 2001, A43:267.
  • 3Roth M, Cowan T E, Key M H, et al. Phys Rev Lett, 2001, 86 : 436.
  • 4Hatchett S P, Brown C G, Cowan T E, etal. Physics of Plasmas, 2007, 7:2 076.
  • 5Schwoerer H, Pfotenhauer S, Jackel O, et al, Nature, 2006, 439:445.
  • 6Gu Yuqiu, Cai Dafeng, Zheng Zhijian, et al. High Power Laser and Partiele Beams, 2004, 16(7): 875.
  • 7Zepf M, Clark E L, Beg F N, et al. Phys Rev Lett, 2003, 90 (6) : 064 801.
  • 8徐雪春,林理彬,蒋波,李军豪,邹萍.一种新型辐射变色膜的γ射线辐照研究[J].强激光与粒子束,2005,17(2):291-294. 被引量:15
  • 9唐翠明,谷渝秋,周维民,杨向东,温贤伦,洪伟,温天舒.100TW激光与等离子体相互作用中质子背向发射的能谱测量[J].强激光与粒子束,2007,19(1):5-8. 被引量:9
  • 10Forslund D W, Kindel J M, Lee K, et al, Phys Rev, 1975, A11: 679.

二级参考文献21

  • 1周维民,谷渝秋,丁永坤,郑志坚,蔡达峰,淳于书泰,温天舒,陈豪,焦春晔,葛芳芳,王光昶,尤永禄玲,何颖玲.超短超强激光与Cu靶相互作用中质子背向发射的实验测量[J].强激光与粒子束,2004,16(11):1406-1408. 被引量:12
  • 2陈文琇,刘爱国.某些添加剂对PVG膜剂量计的效应[J].辐射研究与辐射工艺学报,1997,15(1):15-19. 被引量:2
  • 3Bishop W, Humpherys K, Randtke P. Poly (halostyrene) thin film dosimeters for high doses[J]. Review of Scientific Instruments, 1977,44 : 443-452.
  • 4McLaughlin W, Chen Y D, Soares C, et al. Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams[J]. Nuclear Instruments and Methods in Physical Research Section A, 1991, 302: 165-176.
  • 5Butson M J, Cheung T, Yu P K N. Spatial resolution of a stacked radiochromic film dosimeter[J]. Radiotherapy and Oncology, 2001, 61:211-213.
  • 6Nichiporov D, Kostjuchenko V, Puhl J, et al. Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams[J]. Applied Radiation and Isotopes, 1995, 46(12): 1355-1362.
  • 7Akhavan A, Sohrabpour M, Sharifzadeh M. Preparation of a new chemical radiochromic film dosimeter[J]. Radiation Physics and Chemistry, 2002, 63: 773-775.
  • 8Mikhailik M, Seropegina N, Melnikov M, et al. The kinetics and mechanism of photo-ageing of polyvinylbutyral [J]. European Polymer Journal, 1981, 17: 1011-1019.
  • 9Perry M D, Mourou G. Terawatt to petawatt subpicosecond lasers[J]. Science, 1994, 264: 917.
  • 10Pukhov A. Three-dimensional simulation of ion acceleration from a foil irradiated by a short-pulse laser[J]. Phys Rev Lett, 2001, 86 : 3562-3565.

共引文献22

同被引文献37

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部