摘要
为准确定量铀镀片镀层,重新设计了小立体角定量装置。为满足均匀性检测的需要,设计中考虑了楔型的滑动座以作镀层均匀性测量。本文介绍了小立体角定量装置的建立及对铀镀层定量和非均匀性测量的具体应用。
To quantize the weight of Uranlum-plate accurately, the small solid angle device was redesigned. To fit the requirement of homogeneity check, the sliding base was introduced in the design. This paper presents the detailed application of small solid angle device setup and quantization of Uranium-plate and homogeneity check.
出处
《核电子学与探测技术》
CAS
CSCD
北大核心
2008年第2期278-281,共4页
Nuclear Electronics & Detection Technology
关键词
铀镀片
定量
小立体角装置
均匀性
Uranium-pate, quantization small solid angle device, homogeneity