鉴于ADSS光缆的特异结构、性能及电力线路的特殊性,目前还没有规范化的设计模式可以借鉴,为了在ADSS光缆在各种电压等级的线路上大规模架设中能更好地把握设计规律,在多年实际设计施工经验的基础上,采用理论分析与实践相结合的方法,针对架线杆塔型式、光缆选型、挂点选位择、配盘要求、跨越物距离等方面的问题进行了系统分析,阐述了ADSS光缆线路的设计方法,并对其设计规范的制定提出了建议,对电力通讯领域ADSS光缆规范化设计模式的制定有一定的建设性。
In view of the special structure and property of ADSS optical cable and the speciality of electric power line ,there is not yet normalized design mode to refer to. To investigate into the design laws to string ADSS optical cables across various voltage levels of power lines on a large scale,the paper,based on years of practical pxperiences,by way of combining theory with practice, taking into consideration the type of power transmission post or tower, optical cable type ,the choic of hanging point ,the reguirements of distribution dial ,the spanning distance and so on, elaborates the way of designing ADSS optical cable line and suggets some norms on the designing,which is constructive to the establishment of the mode of the design.
出处
《电力学报》
2008年第2期148-150,163,共4页
Journal of Electric Power
关键词
ADSS光缆
线路
设计
ADSS optical cable
power line
design