放射治疗辐射场剂量分布胶片测量技术的研究进展 被引量:3

原文传递
导出
摘要 随着探测器、影像及计算机技术的发展,对放射治疗定位和剂量精度的要求也越来越高。放射治疗给予的剂量准确与否直接关系到治疗的效果,因此放射治疗剂量的验证是重要的质量保证步骤。胶片剂量计能同时测量一个平面内所有的点剂量,大大减少测量时间;有很高的空间分辨率;可以测量不均匀固体介质中的剂量分布等优点,
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2008年第3期313-314,共2页 Chinese Journal of Radiological Medicine and Protection
  • 相关文献

参考文献17

  • 1IAEA. Radiation oncology physics: a handbook for teachers and students. Vienna: IAEA, 2005.
  • 2Pai U, Indra J. Das TG-69: radiographic film for megavohage beam dosimetry. Med Phys, 2007, 34(6) :2228-2257.
  • 3Chair AN, Blackwell CR, Coursey BM, et al. Radiochromic film dosimetry. Med Phys, 1998,25 ( 11 ) :2093-2115.
  • 4Ju SG, Ahn YC, Huh SJ, et al. Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation. Med Phys, 2002, 29(3) :351-355.
  • 5Bucciolini M, Bounamici FB, Casati M. Verification of IMRT fields by film dosimetry. Med Phys, 2004, 31(1):161-168.
  • 6Fiandra C, Ricardi U, Ragona R. Clinical use of EBT model Gafchromic^TM film in radiotherapy. Med Phys, 2006, 33(11):4314- 4319.
  • 7Cheung T, Butson MJ, Yu PK. Post-irradiation coloration of Gafchromic EBT radiochromic film. Phys Med Biol, 2005, 50(20): 281-285.
  • 8ISP, GAFCHROMIC EBT: SeLf-developing film for radiotherapy dosimetry. New Jersey:ISP,2005.
  • 9马金利,傅小龙,蒋国梁.放射摄片用胶片剂量仪在肿瘤放射物理学中的应用[J].中华放射医学与防护杂志,2004,24(5):483-486. 被引量:7
  • 10Danciu C, Proimus BS, Rosenwald JC, et al. Variation of sensitometfic curves of radiographic films in high energy photon beams. Med Phys, 2001, 28(6) :966-974.

二级参考文献26

  • 1Suchowerska N, Da vison A, Drew J, et al. The validity of using radiographic film for radiotherapy dosimetry. Australas Phys Eng Sci Med,1997,20: 20-26.
  • 2Robar JL, Clark BG. The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry. Med Phys, 1999,26:2144-2150.
  • 3Evans MDC, Schreiner LJ. A simple technique for film dosimetry. Radiother Oncol, 1992,23: 265-267.
  • 4Childress NL, Dong L, Rosen Ⅱ. Rapid radiographic film calibration for IMRT verification using automated MLC fields. Med Phys, 2002, 29:2384-2390.
  • 5Olch AJ. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance. Med Phys, 2002,29: 2159-2168.
  • 6Esthappan J, Mutic S, Harms WB, et al. Dosimetry of therapeutic photon beams using and extended dose range film. Med Phys,2002,29:2438-2445.
  • 7Williamson JF, Khan FM, Sharma SC. Film dosimetry of megavoltage photon beams: a practical method of isodensity-to-isodose curve conversion. Med Phys, 1981,8:94-98.
  • 8Kapulsky A, Mullokandov E, Gejerman G. An automated phantom-film QA procedure for intensity-modulated radiation therapy. Med Dosim,2002,27: 201-207.
  • 9van Battum LJ, Heijmen BJ. Film dosimetry in water in a 23 MV therapeutic photon beam. Radiother Oncol, 1995,34:152-159.
  • 10Stern RL, Fraass BA, Gerhardsson A, et al. Generation and use of measurement-based 3-D dose distributions for 3-D dose calculation verification. Med Phys, 1992,19:165-173.

共引文献6

同被引文献25

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部