摘要 为解决医院废水对周边水体的污染,避免危害人体健康,本文以青岛市某医院洗衣房废水为对象,采取水解酸化-接触氧化工艺进行处理。文中阐述了工艺中各关键构筑物的运行原理和运行情况,工程运行结果表明,经过此工艺处理后的水质能够达到国家相关的排放标准。 This paper takes the technique of hydrolysis acidification-biological contact oxidation to process the wastewater of a hospital in Qingdao to solve the problem of wastewater pollution caused by the laundries of hospitals. The theories and operating conditions of all the key structures are also detailed. The result of operation shows that the water quality can attain the related emission standards issued by Chinese authorities after this special processing.