全血中维生素E和辅酶Q10含量的高效液相色谱法测定 被引量:8

Determination of Vitamin E and CoQ_(10) in Whole Blood by High Perfomance Liquid Chromatography
下载PDF
导出
摘要 建立了一种同时测定全血中维生素E和辅酶Q10的高效液相色谱法。样品经乙醇沉淀蛋白,以正己烷萃取,氮气吹干后,流动相溶解,以甲醇-乙醇(体积比20:80)为流动相,在C18柱(5μm,250mm×4.6mm i.d.)上进行色谱测定。维生素E和辅酶Q10的线性范围皆为1.0~50.0mg/L,检出限分别为0.21、0.15mg/L,相对标准偏差分别为5.2%、5.9%;全血样品的维生素E和辅酶Q10加标回收率分别为97%~115%和90%~112%。 A method for the determination of vitamin E and CoQ10 in whole blood by HPLC was developed. After precipitation of proteins with anhydrous ethanol, vitamin E and CoQ10 in blood were extracted with hexane and then determined with HPLC. A C18 column( Phenomenex, 5μm, 250 mm × 460 mm) and the mobile phase(20 : 80 methanol -ethanol by volume) were used throughout the experiment. The detection wavelength was 292 nm for 8 min, then changed to 275 nm. The linear ranges were 1.0 -50. 0 mg/L, the detection limits were 0.21 mg/L and 0. 15 mg/L, the relative standard deviation(RSD) for vitamin E and CoQ10 were 5.2% and 5.9% , the recoveries were 97% - 115% and 90% -112% for vitamin E and CoQ10, respectively.
出处 《分析测试学报》 CAS CSCD 北大核心 2008年第6期660-662,共3页 Journal of Instrumental Analysis
基金 国家自然科学基金资助项目(30571559)
关键词 维生素E 辅酶Q10 高效液相色谱法 全血 vitamin E CoQ10 high perfomance liquid chromatography blood
  • 相关文献

参考文献6

  • 1KELSO G F, PORTEOUS C M, HUGHES G, et al. Prevention of mitochondrial oxidative damage using targeted antioxidants[J]. Ann N Y Acad Sci, 2002, 959:263 -274.
  • 2MELLORS A, TAPPEL A L. The inhibition of mitochondrial peroxidation by ubiquinone and ubiquinol[ J]. J Biol Chem, 1996, 241:4355-4356.
  • 3LOCKWOOD K, MOSEGARARD S, WU Zufu. Apparent partial remission of breast cancer in high risk[ J]. Mol Aspects Med, 1994, 15:231 -240.
  • 4傅大干,蔡方成,张晓萍.维生素E联合辅酶Q10对幼鼠丙戊酸肝毒性的保护作用[J].实用儿科临床杂志,2006,21(6):364-366. 被引量:9
  • 5CHAVEZ - SERVIN J L, CASTELLOTE A I, LOPEZ - SABATER M C. Simultaneous analysis of vitamins A and E in in- fant milk-based formulae by normal-phase high-performance liquid chromatography - diode array detection using a short narrow-bore column[J]. J Chromatogr: A, 2006, 1122:138 -143.
  • 6孙心齐,焦贺贤,王金中,程岚霞,余海侠.非极性流动相高效液相色谱法定量测定辅酶Q_(10)[J].化学研究,2004,15(3):56-58. 被引量:4