摘要 特快速暂态过电压(VFTO)是由气体绝缘变电站开关操作产生的一种陡波前过电压,它的直接入侵会对变压器绕组的纵绝缘造成极大危害。本文通过理论分析、数值计算和实际测量研究了VFTO作用下变压器绕组并联MOV的保护特性。本文首先建立了变压器绕组的多导体传输线模型(MTLs),推导了基于时域有限差分法(FDTD)的求解迭代公式,通过应用矢量匹配法逼近传输线频变阻抗,解决了时域有限差分法难以处理参数频变效应的问题。然后,建立了变压器绕组并联MOV的多导体传输线模型,并推导了基于FDTD求解该模型的迭代公式。最后,研究了一个连续式变压器绕组模型,测量并计算了该模型在VFTO作用下并联MOV前后的电位分布。对测量结果与计算结果的分析和比较不仅验证了所采用的计算模型和计算方法的正确性,同时也证明了在VFTO作用下用MOV保护变压器绕组的可行性。 Very fast transient overvoltage (VFTO) is a kind of switching impulse overvoltage with very steep front caused by the switching operation in gas insulated substation. Its directly invading to transformer windings may severely damage their longitudinal insulation. In this paper, the protection characteristic of the MOV in parallel with transformer windings under VFTO is studied. First, the multi-conductor transmission lines (MTLs) model for transformer windings is setup, the iterative computing equations based on the finite-difference time-domain method (FDTD) are deduced, and the vector fitting method is adopted to treat the frequency-dependent parameter. Second, the model of the transformer winding in parallel with MOV based on MTLs is developed, and the computing equations to solve the model based on FDTD are deduced. Finally, a practical transformer winding model is studied, the voltage distribution of the transformer windings under VFTO with and without MOV are measured and calculated respectively. The comparison between the calculating results with that of measuring not only indicates the validity of the model and computing method, but also proves the feasibility of using MOV to protect transformer windings from VFTO.
出处 《电工技术学报》 EI CSCD 北大核心 2008年第5期49-55,共7页 Transactions of China Electrotechnical Society
基金 华北电力大学博士科研基金资助项目(93101507)
关键词 变压器 多导体传输线模型 VFTO 时域有限差分法 MOV Transformer, MTLs model, VFTO, FDTD, MOV
  • 相关文献

参考文献17

  • 1阮全荣,施围.GIS隔离开关带分合闸电阻抑制VFTO的研究[J].高电压技术,2005,31(12):6-8. 被引量:43
  • 2Shibuya Y, Fujita S, Hosokawa N. Analysis of very fast transient overvoltage in transformer wingding[J]. IEEE Proceedings-Generation, Transmission and Distribution, 1997, 144(5):461-468.
  • 3Shibuya Y, Fujita S, Tamaki E. Analysis of very fast transients in transformer[J], lEE Proc. Gener. Transm. Distrib, 2001, 148: 377-383.
  • 4Furgal, Jakub. Modelling of overvoltages in transformer windings with internal metal oxide (MO) surge arresters[J]. Modelling,Measurement & Control A, 1995, 63(1-3): 23-32.
  • 5Teranishi T, Ebisawa Y, Yanari T, et al. Approach to suppressing resonance voltage in transformer tap windings[J]. IEEE Transactions on Power Apparatus and Systems, 1983, 102(8): 2552-2558.
  • 6Buthelezi N V, Ijumba N M, Britten A C. Suppression of voltage transients across the tap windings of an auto-transformer by means of ZnO varistors[C]. 2004 International Conference on Power System Technology, Powercon 2004, 2004: 160-164.
  • 7Wen Yuanfang, Zhou Chengke. Experimental studies on the use of MOV in transformer windings inner protection[J]. IEEE Transactions on Power Delivery, 2005, 4(20):1441-1446.
  • 8文远芳,梁毓锦,招誉颐.用MOV作变压器绕组内保护的试验研究[J].中国电机工程学报,1997,17(2):97-101. 被引量:7
  • 9文远芳,招誉颐,梁毓锦.用Calahan法求解MOV保护绕组的波过程[J].电工技术学报,1997,12(2):47-52. 被引量:3
  • 10王赞基.变压器线圈中特快速暂态仿真的建模[J].中国电机工程学报,1996,16(5):299-305. 被引量:65

二级参考文献39

共引文献166

同被引文献53

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部