期刊文献+

Experimental Study of the Recovery Times of Spark Gap Switch with Different Gases 被引量:5

Experimental Study of the Recovery Times of Spark Gap Switch with Different Gases
下载PDF
导出
摘要 A two-pulse method is used to determine the insulation recovery time of the gas spark gap switch with different types of gas applied in a high power accelerator with a water dielectric pulse forming line. At the breakdown voltage of 450 kV, with the vacuum diode voltage of about 200 kV, and a current of 30 kA, recovery characteristics of H2, N2, SF6 were studied. The recovery percentages of the gas breakdown voltage and vacuum diode voltage were determined. The results show that hydrogen has the best recovery characteristics. At a pulse interval of 8.8 ms, the recovery percentages of both the gas breakdown voltage and vacuum diode voltage for hydrogen exceed 95%. For SF6 and N2 with an interval of 25 ms and 50 ms respectively, a 90% voltage recovery was obtained. The experiments also proved that the repetitive rate of the high power accelerator with a pulse forming line is mainly restricted by the gas switch repetitive rate; the recovery percentages of the vacuum diode voltage are limited by the recovery percentages of the gas switch breakdown voltage. The hydrogen switch can be employed for a high repetitive rate-high power accelerator with a pulse forming line. A two-pulse method is used to determine the insulation recovery time of the gas spark gap switch with different types of gas applied in a high power accelerator with a water dielectric pulse forming line. At the breakdown voltage of 450 kV, with the vacuum diode voltage of about 200 kV, and a current of 30 kA, recovery characteristics of H2, N2, SF6 were studied. The recovery percentages of the gas breakdown voltage and vacuum diode voltage were determined. The results show that hydrogen has the best recovery characteristics. At a pulse interval of 8.8 ms, the recovery percentages of both the gas breakdown voltage and vacuum diode voltage for hydrogen exceed 95%. For SF6 and N2 with an interval of 25 ms and 50 ms respectively, a 90% voltage recovery was obtained. The experiments also proved that the repetitive rate of the high power accelerator with a pulse forming line is mainly restricted by the gas switch repetitive rate; the recovery percentages of the vacuum diode voltage are limited by the recovery percentages of the gas switch breakdown voltage. The hydrogen switch can be employed for a high repetitive rate-high power accelerator with a pulse forming line.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第3期379-382,共4页 等离子体科学和技术(英文版)
基金 National Natural Science Foundation of China(No.10675168)
关键词 high current electron accelerator hydrogen switch gas recovery repetitive rate high current electron accelerator, hydrogen switch, gas recovery, repetitive rate
  • 相关文献

参考文献11

  • 1MacGregor S J, Turnbull S M, Tuema F A, et al. 1997, IEEE Trans. on Plasma Sci., 25:110
  • 2Tsuruta K, Takahashi I, Kanzaki Y. 1993, J. Phys. D: Appl. Phys, 26:954
  • 3MacGregor S J, Turnbull S M, Tuema F A, et al. 1995, IEEE Trans. on Plasma Sci.23:798
  • 4Moran S L, Grothaus M G, Hardesty L W. 1992, Five-Pulse, 10-GW, High-Repetition-Rate Hydrogen Spark Switch Experiment. Power Modulator Symposium, Proc. of the 20^th Power. Modulator Symposium, Myrtle Beach, SC, USA. p.376
  • 5Moran S L, Hardesty L W. 1991, IEEE Trans. on Electron Devices, 38:726
  • 6Frost C A, Martin T H, Patterson P E, et al. 1993,Ultrafast Gas Switching Experiments. 9th IEEE International Pulsed Power Conferenc. Albuquerque, New Mexico, USA. p.491
  • 7Dick A R, Macgregor S J, et al. 2000, IEEE Trans. on Plasma Sci., 28:1456
  • 8Tsuruta K, Ebara H. 1991, A model of gas temperature decay after arc extinction of small air gaps. Proceedings of the 3^rd Int. Conf. on Properties and Applications of Dielectric Materials Ibaraki Univ.Hitachi, Japan. p.377
  • 9Deng X S, Chen S, Li D J. 1993, High Voltage Engineering, 14:7
  • 10Yin Y, Liu J L, Yang J H, et al. 2006, Parameters Analysis of Spark Gap and Simulation of Gas Temperature decay. 1^st Euro-Asian Pulse Power Conf., Chengdu, China

同被引文献29

引证文献5

二级引证文献13