摘要
某型试制中的分体空调室外机长期可靠性运行后的配管出现裂纹,且振动较大。利用ANSYS软件建立了压缩机-配管系统的虚拟样机,通过实验确定了压缩机的激励输出,对施加了压缩机等效载荷的系统进行了动力学分析。根据分析结果对系统的管路进行了改进,仿真分析和实验结果都取得了良好的效果。
In reliability inspections after long term outdoor operation of one trial-manufacturing sample of split type air-conditioner, crackles in the air conditioner compressor pipes are found and the pipe vibration is evident. Therefore a virtual prototype of compressor-pipe system is constructed with ANSYS. The excitation output of the compressor is determined by experiments, dynamic analyses of the system exerted the equivalent load of compressor is performed, by means of which pipe system is improved. Good results are obtained in both simulation analyses and experiment.
出处
《顺德职业技术学院学报》
2008年第2期11-14,共4页
Journal of Shunde Polytechnic
关键词
空调配管
动力学
模拟研究
air conditioner compressor pipe
dynamics
simulation research