摘要
根据GB50411-2007《建筑节能工程施工质量验收规范》中保温板材与基层的粘结强度应做现场拉拔试验,提出了建筑保温板材现场拉拔的检测范围,对粘结强度指标值的确定及判定要求。该方法操作简单,安全可靠,测量准确,具有实际指导意义。
According to 《Code for acceptance of energy efficient building construction》(GB50411-2007), field pull out tests should be done for insulation plate and the bond strength, the test scale of field pulling out of insulation plate about construction conserves energy, and the index value of bond strength are proposed, operation is simple, safe and reliable, measuring is accurate in method, and this method has a significance of actual guidance.
出处
《上海计量测试》
2008年第2期32-34,共3页
Shanghai Measurement and Testing
关键词
保温层
粘结强度
试验方法
thermal insulation layer
test methods