期刊文献+

高大平房仓玉米就仓干燥试验研究 被引量:9

IN-STORE DRYING OF CORN IN LARGE WAREHOUSES
下载PDF
导出
摘要 选取3间试验仓,分别采用地上笼离心风机压入式通风降水、立体插管通风降水以及地上笼和立体插管通风相结合通风降水的方法,进行高大平房仓玉米就仓干燥试验研究。通过对比分析得出,地上笼和立体管通风相结合,能简单有效地对高粮堆玉米进行就仓干燥降水处理,保证仓房的利用率,并能节约成本。 Three large warehouses were selected for in-store drying of corn. Three methods which are above-ground centrifugal fan, intubation , and the combination of both of them were adopted respectively. By com-parison and analysis of the three methods, the result showed that in-- store drying of combination of above-ground wentilation with intubation can dry the corn with high moisture content which was stored in high grain bulk simply and effectively. It can also assure the utilization ratio of the warehouse and save the cost.
出处 《粮食储藏》 2008年第3期16-20,共5页 Grain Storage
基金 国家"十一五"科技支撑计划项目资助(2006BAD08BO5) 江苏省高技术计划(农业)项目资助(BG2007340)
关键词 高大平房仓 就仓干燥 高水分玉米 large warehouse, in--store drying, high moisture content corn
  • 相关文献

参考文献2

二级参考文献1

共引文献21

同被引文献57

引证文献9

二级引证文献74

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部