期刊文献+

高层建筑玻璃幕墙的风压和风振计算 被引量:4

The Wind Pressure and Calculation of Wind Induced Vibration for Glass Cladding of Tall Buildings
下载PDF
导出
摘要 该文根据风载及玻璃幕墙的变形特点,探讨了简便实用的玻璃幕墙风载计算公式;用板的随机振动理论,建立了幕墙风振响应、风振力、风振系数的严密计算公式;针对国际流行的Davenport风谱,给出了简便实用的风振系数表达式。结果也适用于其它材料的幕墙,为工程设计提供了方便。 In this paper, according to the characteristics of wind load and deformation of glass cladding, a simple and practical calculating formula for wind load of glass cladding is presented; the strict calculating formulas for wind induced response, wind induced vibration force and coefficient of glass cladding are established; according to the international popular Davenports wind spectrum, a convenient and practical calculating formula for wind induced vibration coefficient is given. These results can be applied to the claddings made of other materals,which provides convenience for engineering design.
出处 《南京理工大学学报》 EI CAS CSCD 1997年第4期370-373,共4页 Journal of Nanjing University of Science and Technology
关键词 玻璃 抗风结构 幕墙 高层建筑 风压 风振 building engineering, glass, windresisting structures, design cladding