摘要
结合沈阳某别墅小区中央空调机房内降噪工程的实际案例,对水源热泵机组产生噪声的机制及噪声治理方法进行分析,介绍在中央空调机房内多噪声源、噪声频带范围较宽的情况下对噪声的综合治理。
Analyzes the theories of noise produced by water-source heat pump, combined with the noise-reducing solution for water-source heat pumps within cenntral air-conditioner room of a villa community in Shenyang, and discusses the methods of noise-reducing solution. Introduces the comprehensive solution for the multiple sources and broadband noise.
出处
《制冷与空调》
2008年第B06期43-45,共3页
Refrigeration and Air-Conditioning
关键词
水源热泵
中央空调机房
噪声
water-source heat pump
cenntral air-conditioner room
noise