摘要
Under basic condition,phenol has strong sensitivity quenching ability to electrogenerated chemiluminescence produced by fluorescein-potassium persulphate system.Based on this system,a electrogenerated chemiluminescence method has been established for the determination of phenol.The method is simple,convenient and sensitive.The linear range is 1.00×10-6mol/L^1.00×10-3 mol/L with the detection limit of 2.81×10-7 mol/L.The RSD is 2.76 % for 1.00×10-5 mol/L phenol(n=11).The method has been used for determination of phenol in man-made samples with satisfactory results.
Under basic condition, phenol has strong sensitivity quenching ability to electrogenerated chemiluminescence produced by fluorescein - potassium persulphate system. Based on this system, a electrogenerated chemiluminescence method has been established for the determination of phenol The method is simple, convenient and sensitive. The linear range is 1. 00 × 10^-6mol/L - 1.00 × 10^-3mol/L with the detection limit of 2. 81 × 10^-7 mol/L. The RSD is 2. 76 % for 1.00 × 10^-5 mol/L phenol (n = 11 ). The method has been used for determination of phenol in man-made samples with satisfactory results.
出处
《化学研究与应用》
CAS
CSCD
北大核心
2008年第5期660-662,共3页
Chemical Research and Application
关键词
电致化学发光
荧光素
过硫酸钾
苯酚
electrogenemted chemiluminescence
fluorescein
potassium persulphate
phenol