摘要 在确定碳纤维加固混凝土构件防火方法的基础上,利用有限元分析软件ANSYS对火灾下有防火保护的碳纤维加固混凝土构件的温度场进行分析,并获得构件截面温度分布的规律。结果表明:碳纤维加固构件的温度场计算结果与试验结果符合较好,为进一步研究火灾下有防火保护的碳纤维加固混凝土构件的力学性能和耐火极限创造了条件。 The temperature field of insulated carbon'FRP-strengthened concrete members exposing to fire was analyzed based on determination of fire insulation systems, and the temperature contours of sections were achieved. The calculated results are shown to agree well with the experimental data. It is possible for further researches on the mechanical behavior and fire performance of carbon FRP-strengthened concrete members under fire condition.
出处 《工业建筑》 CSCD 北大核心 2008年第6期117-121,共5页 Industrial Construction
关键词 碳纤维加固混凝土构件 火灾 温度场 非线性有限元分析 carbon FRP-strengthened concrete member fire temperature field nonlinear finite analysis
  • 引文网络
  • 相关文献

参考文献10

  • 1Williams B. Fire Performance of FRP-Strengthened Reinforced Concrete Flexural Members. PhD thesis, Department of Civil Engineering, Queen's University, Kingston, Ontario, Canada, 2004.
  • 2Bisby L A, Green M F, Kodur V K R. Modeling the Behavior of Fiber Reinforced Polymer-Confined Concrete Columns Exposed to Fire. Journal of Composites for Construction, ASCE, 2005, 9( 1 ) : 15 - 24.
  • 3Blontrock H, Taerwe L, Matthys S. Properties of Fiber Reinforced Plastics at Elevated Temperatures with Regard to Fire Resistance of Reinforced Concrete Members. // Fourth International Symposium on Fiber Reinforced Polymer Reinforced for Reinforced Concrete Structure,Petroit, Michigan, American Concrete Institute, SP188 - 5,1999:43 - 54.
  • 4Richard Barnes, James Fiden. Performance in Fire of Small-Scale CFRP Strengthened Concrete Beams. Journal Of Composites for Construction, ASCE, 2006,10(6) :503 - 508.
  • 5ACI, ACI 440. 2R - 02: Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. Farmington Hills : American Concrete Institute, 2002 : 113.
  • 6Lie T T, Denham E M A. Factors Affecting the Fire Resistance of Circular Hollow Steel Columns Filled with Bar-reinforeed Concrete. NRC-CNRC Internal Report, 1993(651 ).
  • 7Lie T T. Fire Resistance of Circular Steel Columns Filled with BarReinforced Concrete. Journal of Structural Engineering, 1994, 120(5 ) : 1489- 1509.
  • 8Luke A Bisby, Venkatesh K R Kour, Mark F Green. Fire Endurance of Fiber-Reinforced Polymer-Confined Concrete Columns. ACI Structural Journal, 2005(11/12) :883 - 891.
  • 9Bisby L. Fire Behavior of Fiber-Reinforced Polymer (FRP) Reinforced or Confined Concrete. [ PhD thesis]. Ontario: Department of Civil Engineering, Queen's University, 2003.
  • 10Venkatesh K R Kodur, Luke A Bisby, Mark F Green. Experimental Evaluation of the Fire Behaviour of Insulated Fibre-Reinforced-PolymerStrengthened Reinforced Concrete Columns. Fire Safety Journal, 2006, 41:547 - 557.