期刊文献+

生物氧化塔/过滤/RO工艺处理二级出水并回用 被引量:6

Biological Oxidation Tower/Filtration/RO Process for Treatment of Secondary Effluent and Reuse
下载PDF
导出
摘要 大连北海热电厂以某污水厂二级处理出水为水源,采用生物氧化塔/纤维束和砂滤二级过滤/RO组合工艺,建设了污水深度处理与回用工程(主要用作循环冷却水和锅炉补水处理系统的原水)。运行结果表明,采用单膜法进行污水深度处理是可行的,具有处理效果好、运行稳定、工程投资省、运行费用低等优点。 Taking the secondary effluent from a WWTP as source water, the combined process of biological oxidation tower, secondary filter with fiber bundles and sand filtration and reverse osmosis (RO) was used to construct an advanced wastewater treatment and reuse project in Dalian Beihai Thermal Power Plant. The advanced treatment effluent is mostly used as recirculated cooling water and boiler make-up water. The operation result indicates that using single membrane method is feasible for advanced wastewater treatment. The combined process has advantages such as good treatment effect, stable operation, small investment, low operation cost and so on.
出处 《中国给水排水》 CAS CSCD 北大核心 2008年第12期79-82,共4页 China Water & Wastewater
关键词 污水深度处理 单膜法 反渗透 再生回用 advanced wastewater treatment single membrane method reverse osmosis reclamation and reuse
  • 相关文献

参考文献4

二级参考文献16

  • 1属富夫 矶冈富 徐平.膜分离技术在环保领域的应用[A]..分离膜技术应用论文汇编[C].北京:美国海德能公司,2002..
  • 2Anderson J.国际回用水的应用实例研究[A]..21世纪国际城市污水处理及资源化发展战略研讨会与展览会会议论文[C].北京,2001..
  • 3Zhai Jianwen, Yang Yan. A comparison of pretreatments of RO procemes for wastewater reclamation[ A]. The 2ed International Conference on Application of Membrane Technology[C]. Beijing: 2002.
  • 4Lozier J, Bergman R. Membrane proceasea in water reuse[A]. Proceedings of Water Reuse Symposium[C]. Denver, Colorado: 1994.
  • 5Leslie G L, Dunivin W R, Gabilet P, et al. Pilot testing of microfiltration and ulttafiltration upstream of reverse osmosis during reclamation of municipal wastewater[A]. Proceedings of ADA,Biennial Conference[C],Monterey California: 1996.
  • 6Henmi M, Matsuka N,et al. Newly developed wastewater treatment ( 8 ) systems using separation membranes[A].Water Reuse & Desalination Conf[ C]. Riyadh. 2003. 235~245.
  • 7Cote P,Buisson H,Pound C,et al.Immersed membrane activated sludge for the reuse of municipal wastewater[J].Desalination,1997,113:189~196.
  • 8Lozier J C. Wastewater reclamation pilot study city of Mcallen[R]. Texas Water Treatment Technology Program Report No. 26, Bureau of Redamation, 1998.
  • 9Glucina K, Laine J M. Lyonnaise des Eaux - Cirsee, et al. Integrated membrane systems for surface water treatment: Comparison of UF vs conventional pretreatment[A]. Membrane Technology Conference- The Future of Purer Water [ C]. San Antonio: TX US, 2001. 867~882.
  • 10Verberka J Q J C, Worma G I M, Futselaarb H, et al.Combined air- water flush in dead - end ultrafiltration:water science and technology[ J ]. Water Supply, 2001,1(5/6) :393~402.

共引文献41